Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsPower Quality Analyzer

Portable Three Phase Power Data Logger quality Analyzer,power quality and energy analyzer

Good quality High Voltage Resonant Test System for sales
Good quality High Voltage Resonant Test System for sales
Product is good by performance, yes it is good for xxxxxx market.

—— Mr Dudani

Your product received very good, we will order one more piece

—— JS

You are very nice company. Thanks for your hospitality i spend very informative in your office

—— Yousri

Good for whatever the product or service, you got my trust through this deal.

—— Rahul

Very reliable supplier and partner, solving my question with great patience and perfession.

—— Gaurav

I'm Online Chat Now

Portable Three Phase Power Data Logger quality Analyzer,power quality and energy analyzer

China Portable Three Phase Power Data Logger quality Analyzer,power quality and energy analyzer supplier
Portable Three Phase Power Data Logger quality Analyzer,power quality and energy analyzer supplier Portable Three Phase Power Data Logger quality Analyzer,power quality and energy analyzer supplier Portable Three Phase Power Data Logger quality Analyzer,power quality and energy analyzer supplier Portable Three Phase Power Data Logger quality Analyzer,power quality and energy analyzer supplier

Large Image :  Portable Three Phase Power Data Logger quality Analyzer,power quality and energy analyzer

Product Details:

Place of Origin: Hubei, China
Brand Name: GDZX
Certification: CE , ISO
Model Number: ZXDN-3561

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Price: $5,000.00 - $8,000.00 / Sets
Packaging Details: Carton or wooden box
Delivery Time: 7~10 work days
Payment Terms: L/C, D/A, D/P, T/T
Supply Ability: 100 Set/Sets per Month
Contact Now
Detailed Product Description
Product Name: Three Phase Portable Power Quality Analyzer Measuring Range: 1000V TRMS
Frequency: 40~70Hz Brand: GDZX
Application: Power Quality Analyzer Warranty: 1 Year

 

Product Introduction :

 

Power Quality Analyzer is a portable device of testing and analyzing power system operation quality. It monitors and collects data in long running time, also provides harmonic analysis and power quality analysis. Meanwhile, it equips with data analysis software, by which the measure data can be uploaded to PC.

 

FUNCTIONS
NO. Items Description
1 U / I / F Measure three-phase voltage, line voltage voltage, three-phase current, Line line current, Frequency etc, display RMS, peak value, wave/peak ratio, waveform diagram, trend map, etc..
2 Harmonic measurement Measure the fundamental wave of voltage and current,2~50 th harmonics, results include effective value, content rate, THD, display bar graph, trend map, etc
3 Inter-harmonics measurement Measure 0.1~19.9th U I inter-harmonics, results include harmonic component and subset RMS, display bar and trend chart
4 Power/energy measurement Measure 3P3W/3P4W apparent power, active power,reactive power,power factor etc, display trend map
5 Three-phase Unbalance measurement Measure the positive sequence component, negative sequence component, zero sequence component, negative sequence imbalance degree and zero sequence imbalance degree of 3p3w/3p4w voltage and current, display phase angle, vector graph, trend chart of three phase voltage and current.
6 Flicker Measure 1min, 10mins, 2 hours Flicker Measurement
7 Voltage dips and swells, interruption Measure and record voltage dips and swells, interruption events
8 Surge current Measure and record surge current event
9 Harmonic power Measure 2~30th harmonic power,display bar graph, trends map
10 Power wave Measure the rapid change (active power, reactive power, Apparent power) within the setting time: 1~5mins
11 Transient Measure transient Events longer than 20μs
12 Monitoring records Record for a long time the Steady-state Power quality Factors: ,include voltage/current/ frequency / harmonic power/power/ Three-phase Unbalance/ Fluctuation / flicker, The recording time can be set from 3 to 30 minutes
13 Digital Oscilloscope Check the voltage and current waveform

 

Accuracy index of various detection functions :

 

Item Measuring range Measurement accuracy Remarks
Voltage / current / frequency

three-phase voltage:1000V TRMS

Null line voltage:70V(TRMS)

three-phase current:6000A(TRMS, different current sensor for options)

Null line current:25A(TRMS, different current sensor for options)

Frequency:40~70Hz

voltage:0.1%rdg ±0.05%f.s

current:0.2%rdg ±0.05%f.s

Frequency:±0.01Hz

A phase voltage frequency as the the measuring frequency
Harmonic measurement

voltage harmonic:THD+ fundamental wave +2~50th harmonics

current harmonics:THD+ fundamental wave +2~50th harmonics

voltage harmonic:

Uh≥1%UN,±5%Uh;

Uh<1%UN,±0.05%UN;

current harmonics:

Ih≥3%IN,±5%Ih;

Ih<3%IN,±0.15%IN;

 
Measurement of Inter-harmonics

voltage harmonic:0.1~19.9th Inter-harmonics

current harmonics:0.1~19.9th Inter-harmonics

voltage inter-harmonics:

Uih≥1%UN,5%Uih;

Uih<1%UN,0.05%UN;

current inter-harmonics:

Iih≥3%IN,5%Iih;

Iih<3%IN,0.15%IN;

 
Measurement of Power /electric energy

Active power:700kW

Apparent power:700kVA

reactive power:700kVAR

power factor:0.00~1.00

Active Power:10000kWh

Apparent power:10000kVAh

reactive power:10000kVARh

Average power factor:0.00~1.00

Active power:reading data±0.5%

Apparent power:reading data±0.5%

reactive power:reading data±0.5%

power factor:reading data±0.005

 
Measurement of Three-phase Unbalance

Fundamental voltage:1000V(TRMS)

Fundamental current: 6000A(TRMS)

Fundamental frequency: 40~70Hz

Phase angle:0~360o

Unbalance:0.0%~100%

voltage:0.1%rdg ±0.05%f.s

current:0.2%rdg ±0.05%f.s

frequency:±0.01Hz

Angle: ±0.3 o

Voltage balance: ±0.2%

Current balance: ±0.2%

A phase voltage frequency as the the measuring frequency
Voltage Flicker 1min Flicker Measure, short time Flicker, long time Flicker

1min Flicker:±5.5%

10min Flicker:±5%

2hours Flicker:±5%

 
Voltage dips / swell / interruption Measure and record the single or multiple phase voltage disp and swells, interruption Half-wave RMS, start time, last time, end time, error±10ms Max 40 events
Surge current Measure and record single-phase and Multiple-phase surge current event Half-wave RMS, start time, last time, end time, error±10ms Capture an event then stop
Harmonic power

Total harmonic power order:1~30th

Harmonics total active power:∑P

Harmonics total reactive power:∑Q

Positive-sequence harmonics total active power:+∑P

Negative harmonics total active power:-∑P

Positive-sequence harmonics total reactive power:+∑Q

Negative harmonics total reactive power:-∑Q

Power reading:±0.5%  
Power wave Test active reactive apparent half-wave power value, in 1 minutes, 3 minutes, 5 minutes, record power trends Half-wave power reading:±0.5%  
Transient Transient voltage over 120% of the rating

Measure events minimum period above 20us,

Event capture probability: 98.7%

One time measurement can store 20 events
Monitoring records Record: voltage, current, frequency, voltage and current harmonics (THD+1~25th order), three phase unbalance, active power, reactive power, power factor, fluctuation, flicker

Save time interval:3s~30min

Monitoring time is 16 hours when interval is 3 seconds; 960 hours when interval is set as 30 minutes

 
Digital Oscilloscope Display the Instantaneous waveform of three-phase voltage, three-phase current, Null line voltage, Null line current

Max sampling frequency 200kHz

Min sampling frequency:100Hz

 

 

1. Voltage signal input circuit:
direct input
Input impedance:1MΩ, 20pF
measurement range:RMS 700V
Power dissipation:< 0.5VA/ phase
2. current signal input circuit:
indirect input
measurement range:TRMS 1A,5A,10A,100A,500A,1000A,3000A(Select proper current sensor)
Power dissipation:<0.5VA/ phase
3. measuring signal frequency range: 40Hz~70Hz
4. display screen:5.7 " 640×480 color graphic LCD + touch screens
5. memory capacity:128M bit FLASH
6. External Memory Interface:USB (U disk can inserted)
7. operating current:rechargeable Li-battery, once fully charged working hours at 5~6hs
8. external source of power:AC100~240V/DC16.8V-1A power adapter / charger

 