31500kVA Transformer Testing Equipment With 320x240 LCD Display

31500kVA Transformer Testing Equipment With 320x240 LCD Display
31500kVA Transformer Testing Equipment With 320x240 LCD Display 31500kVA Transformer Testing Equipment With 320x240 LCD Display 31500kVA Transformer Testing Equipment With 320x240 LCD Display 31500kVA Transformer Testing Equipment With 320x240 LCD Display 31500kVA Transformer Testing Equipment With 320x240 LCD Display

Large Image :  31500kVA Transformer Testing Equipment With 320x240 LCD Display

Product Details:
Place of Origin: CHINA
Brand Name: GDZX
Certification: ISO9001
Model Number: ZX-BZL
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: 1800USD/PCS
Packaging Details: carton
Delivery Time: 5--8 working days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 1000PCS/MONTH
Detailed Product Description
Capacity Measuring Range:: 30kVA ~ 31500kVA Voltage Measurement Accuracy:: ± (0.2% + 3digits)
Power Supply:: 220V 50Hz Warranty:: 3 Years
Weight:: 10kg Frequency Range:: 40 ~ 65Hz
Current Measuring Range:: 0 -100A Auto-switch The Measurement Range
High Light:

320x240 LCD Transformer Testing Equipment

,

31500kVA Transformer Testing Equipment

ZX-BZLTransformer On Site Transformer Capacity No-load & Load Tester

Functional characteristics

1. Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses, capability.

2. Three Methods.

3. Do three-phase transformer no-load, load test, the instrument can automatically determine the wiring is correct, and shows three-phase voltage and current vector map.

4. Single machine can do the following 100KVA distribution transformer full load current experiment; in one third of the rated current, complete 250KVA distribution transformer load the following test (in one third of the rated current, the instrument can be converted to load loss under rated current parameters, the machine is mainly used in the test bed with integrated supporting the use of transformers.

5. All the related test results are automatically corrected. Instrument can automatically such as: the waveform correction, temperature correction, non-rated voltage correction, calibration, and other non-rated current correction, so that more accurate test results.

6. 320x240 large screen, high brightness LCD display, full Chinese menu and operations to achieve prompt and friendly man-machine dialogue, touch buttons make the operation more convenient, wide LCD with brightness adjustment, can be adapted to the various summer and winter season.

7. Comes with real-time clock, automatically recording test date, time, the preservation of favorable results, management.

8. Panel-type thermal printer, the scene quickly print test results.

9. Data (test sample set, the measurement results, the test of time, etc.) with power-down storage and browsing features, you can store 500 set of experimental results with computer on-line data transfer.

10. Allows an external voltage transformer and current transformer for extended range of measurement, any measurable parameter is the test product.

 

Technical indicators

1, Test Item

² RMS phase voltage :Uab,Ubc,Uca;

² Average value of three-phase AC voltage :/Uab,/Ubc,/Uca;

² Three-phase current RMS :Ia,Ib,Ic;

² Percentage of no-load loss and no-load current: Po,Io%;

² Load loss, impedance voltage, and the percentage of short-circuit impedance: Pt,ekt,Zt;

² Any given temperature, load loss, the percentage impedance voltage and short circuit impedance;

² Any given temperature, load loss, the percentage impedance voltage and short circuit impedance.

Parameters

² Capacity measuring range : 30kVA ~ 31500kVA

² Current measuring range: 0 -100A auto-switch the measurement range

² Current measurement accuracy: ± (0.2% + 3digits)

² Voltage measurement range: Line Voltage0-750V;phase voltage 0-450V, auto-switch the measurement range

² Voltage measurement accuracy: ± (0.2% + 3digits)

² Insulation resistance: > 100M

² Leakage current: <3.5mA

² Dielectric strength: the power connection on the chassis can withstand: 1500V

² External transformer can broaden the scope of measurement instruments;

² Frequency Range: 40 ~ 65Hz, accuracy class 0.2;

² Power Input: AC220V ± 10%

Basic measurement accuracy voltage and current ±(reading*0.2%+2 Bits)
Power (0.2<=cosφ<=1) ±(reading*1.0%+2 Bits)
Voltage measurement range AC 50V-850V
Current measurement range AC 0.5A-100A
Working temperature - 10 ~40ºC
Storage temperature - 20 ~50ºC
Environmental humidity 10% - 85%
Shape size 395 x 295 x 175mm
Weight 5kg (excluding test line)