Brand: | GDZX | Maximum Output Power: | 300VA/phase |
---|---|---|---|
Model: | ZX-1200 | Temperature: | -10℃~+40℃ |
Power Supply: | 120v-240v ±10% | Humidity: | ≤90% |
Accuracy: | 0.1% | ||
High Light: | protection relay test equipment,protective relay tester |
Wuhan GDZX Power Equipment Co.,Ltd OFFER YOU :
1: FACTORY DIRECT PRICE.
2: NICE QUALITY.
3: QUICK SHIPPING WITHIN 15 DAYS.
4: SMALL ORDER WELCOME..
5: ONLINE PAYMENT.
6: SUPPORT One year free warranty, three years quality assurance, lifetime maintenance.
7: AFTER SALES SERVICES 24/7
8. Respect every customer .
Six Phase Relay Protection Tester Current Reach To 40A Output Accuracy 0.1A ~1A
ZX-1200 microcomputer relay protection Tester adopts high performance IPC as the controller, Window XP operating system, large size and color TFT screen, and industrial keyboard. The front panel is provided with a plurality of USB ports which is convenient for data access, data communication and software upgrades.
Features:
1. Windows XP operation system, multiple keyboard shortcuts, user-friendly interface
2. High performance embedded IPC and high resolution TFT color LCD displaying massive information
3. ultra-thin keyboard and touch pad, operation just like ordinary PC
4. USB communication interface, convenient for data access and software maintenance
5. Test without auxiliary devices, auto display and record data, auto finish vector graph and characteristic curve
6. Advanced D/A converter which ensured high precision waveform, good linearity and nice transient response and amplitude-frequency characteristic
7. Direct output of ac voltage/current, dc voltage/current, variable amplitude/angle/frequency
8. high fidelity linear power amplifier, no wave distortion or peak clipping even when current reach the maximum
9. Switch value input terminal can Intelligently identify active or passive contact and polarity
10. Can scan all kinds of safety setting, real-time storage and print and vector diagram display
11. Carrying box design, little volume, good heat radiation, little weight
12. Self-protection function
Product parameters:
ITEM/MODEL | ZX-1200 | ZX-1600 | |||
AC current source | Current source with six phase common neutral point, current up/down time<100μs | ||||
Maximum output power | 300VA/phase | 450VA/phase | |||
Output accuracy | 0.1A~1A: accuracy: ±5mA | 0.1A~1A: accuracy: ±5mA | |||
1A~10A: accuracy: ±0.1% | 1A~10A: accuracy: ±0.1% | ||||
10A~30A: accuracy ±0.2% | 10A~40A: accuracy ±0.2% | ||||
Resolution | 0.1A~10A: 1mA | 0.1A~10A: 1mA | |||
10A~30A: 5mA | 10A~40A: 5mA | ||||
Single phase continuous output time | 1A~10A: No limit | 1A~10A: No limit | |||
10A~20A: ≥60sec | 10A~20A: ≥90sec | ||||
20A~30A: ≥50sec | 20A~30A: ≥20sec 30A~40A: ≥15sec | ||||
AC voltage source | Voltage source with six phase common neutral point, current up/down time<100μs | ||||
Maximum output power | ≥75VA/phase | ||||
Output accuracy | 1V~5V: ±5mV | 1V~5V: ±5mV | |||
5V~120V: ±0.2% | 5V~125V: ±0.1% | ||||
Resolution | 1V~5V: 1mV | 1V~5V: 1mV | |||
5V~120V: 5mV | 5V~125V: 5mV | ||||
DC current source | Single phase output range | 0A~+10A | -10A~+10A or 0~20A | ||
Maximum output power | 200VA/phase | 300VA/phase | |||
Output accuracy | ±0.1A~±2A: ±10mA | ±0.1A~±2A: ±10mA | |||
±2A~±10A: ±0.5% | ±2A~±10A: ±0.2% | ||||
Resolution | 5mA | ||||
DC voltage source | Output range | -150V~+150V | -150A~+150V or 0~300V | ||
Maximum output power | ≥100VA | ||||
Output accuracy | ±1V~±5V: ±20mV ±5V~±150V: ±0.5% | ±1V~±5V: ±10mV ±5V~±150V: ±0.2% | |||
Resolution | ±1V~±5V: 5mV | ±1V~±5V: 5mV | |||
±5V~±150V: 10mV | ±5V~±150V: 10mV | ||||
AC source angle | phase range | 0°~360° | |||
Accuracy | ±0.3° | ±0.1° | |||
Resolution | 0.1° | 0.01° | |||
AC source frequency | range | 10~1000Hz | 1~2000Hz | ||
can overlap 2~20 order harmonic with any amplitude and direct current | |||||
Output accuracy | 10Hz~65Hz ±0.005Hz | 1Hz~65Hz ±0.001Hz | |||
65Hz~1000Hz ±0.02Hz | 65Hz~2000Hz ±0.02Hz | ||||
Resolution | 0.001Hz | 0.001Hz | |||
Timing accuracy | 1ms~1S ±10ms | 1ms~1S ±1ms | |||
1S~999999S ±0.2% | 1S~999999S ±0.2% | ||||
Input switch | 8 independent switch contact input, auto identify polarity of the active contact | 16 independent switch contact input, auto identify polarity of the active contact | |||
Output switch | 4 pairs programmable idle contact output | 8 pairs programmable idle contact output | |||
contact capacity: 250VDC, 0.5A or 250VAC,0.5A | |||||
Synchronism | voltage current ≤50μS | voltage current ≤10μS | |||
Power supply | AC input voltage | Rated value: 220V ± 10% | |||
Reference value: 220V ± 2% | |||||
AC power frequency | Rated value:50Hz ± 10% | ||||
Reference value:50Hz ± 2% | |||||
Working environment | Temperature | -10℃~+40℃ | |||
Humidity | ≤90% | ||||
Air pressure | 80~110kPa |