Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Wuhan GDZX Power Equipment Co., Ltd
Home ProductsCT PT Analyzer

ISO9001 AC 220V Variable Frequency CT PT Testing Equipment

China Wuhan GDZX Power Equipment Co., Ltd certification
China Wuhan GDZX Power Equipment Co., Ltd certification
Product is good by performance, yes it is good for xxxxxx market.

—— Mr Dudani

Your product received very good, we will order one more piece

—— JS

You are very nice company. Thanks for your hospitality i spend very informative in your office

—— Yousri

Good for whatever the product or service, you got my trust through this deal.

—— Rahul

Very reliable supplier and partner, solving my question with great patience and perfession.

—— Gaurav

I'm Online Chat Now

ISO9001 AC 220V Variable Frequency CT PT Testing Equipment

ISO9001 AC 220V Variable Frequency CT PT Testing Equipment
ISO9001 AC 220V Variable Frequency CT PT Testing Equipment
video play

Large Image :  ISO9001 AC 220V Variable Frequency CT PT Testing Equipment

Product Details:
Place of Origin: China
Brand Name: GDZX
Certification: ISO9001
Model Number: ZXHQ-Y
Payment & Shipping Terms:
Minimum Order Quantity: 1Set
Packaging Details: packing bag
Delivery Time: 7-20 work days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 50pcs/month
Detailed Product Description
Input Power Voltage: AC220V ± 10%, 50Hz / 60Hz ± 10% Output Voltage: 0.1 ~ 125V (AC)
Output Current: 0.001 ~ 5A (RMS) Output Power: 300VA
He Highest Equivalent Inflection Point Voltage: 45KV Working Conditions: -10 ℃ ~ 50 ℃, Humidity: ≤90%
Size: 485mm × 356mm × 183mm Weight: 15Kg
High Light:

220V CT PT Testing Equipment

,

ISO9001 CT PT Testing Equipment

,

AC CT PT Analyzer


AC 220V Variable Frequency CT PT Test Analyzer ct pt testing equipment

Features

The CT PT analyzer is used for the following tests of current transformers:

1. Excitation characteristic test

2. Turn ratio detection

3. Verification of ratio difference and angle difference

4. Polarity check

5. Secondary winding resistance measurement

6. Secondary load measurement

7, 5% and 10% error curve measurement

8. CT transient characteristics test and analysis

9. CT nameplate automatic inference

10. Measurement of CT parameters such as inflection point voltage / current, accurate limit factor, instrument security factor, secondary time constant, residual magnetic coefficient, accuracy level, saturation and undersaturation and inductance, inflection point electromotive force, limit electromotive force and area factor

11. Hysteresis loop measurement of current transformer core



The CT PT analyzer can also be used for the following tests of voltage transformers:

1. PT turns ratio detection

2. PT polarity check

3. PT secondary winding resistance measurement

4. PT secondary load measurement

The application of the device mainly includes:

1. Parameter verification of CT nameplate

2. Parameter verification when CT is connected to current load

3. Analyze the impact of CT's transient characteristics on the relay protection device.

4. PT nameplate parameter verification

5. PT secondary load verification

 


Technical Indicators

1. Test standard basis: IEC60044-1, IEC60044-2, IEC60044-5, IEC60044-6, GB1207, GB1208, GB16847, GBT4703, C57.13

2. Input power voltage: AC220V ± 10%, 50Hz / 60Hz ± 10%

3. Output voltage: 0.1 ~ 125V (AC)

4. Output current: 0.001 ~ 5A (RMS)

5. Output power: 300VA

6. The highest equivalent inflection point voltage: 45KV

7. Current measurement: Range: 0 ~ 10A (automatic range 0.1 / 0.4 / 2 / 10A), error <± 0.1% + 0.01% FS

8. Voltage measurement: Range: 0 ~ 200 V (automatic range 1/10/70 / 200V), error <± 0.1% + 0.01% FS

9. Turn ratio measurement: range: 1 ~ 30000, 1 ~ 2000 error <0.05%, 2000 ~ 5000 error <0.1%, 5000 ~ 30000 error <0.2%

10. Phase measurement: Accuracy: ± 2min, resolution: 0.01min

11. Measuring range of secondary winding resistance: range: 0 ~ 8KΩ (automatic range 2/20 / 80Ω / 800Ω / 8kΩ)

Error <0.2% RDG + 0.02% FS, maximum resolution: 0.1mΩ

12. Temperature measurement: -50 ~ 100 degrees, error <3 degrees 

13. CT secondary load measurement: 0 ~ 160ohm (2/20 / 80ohm / 160ohm)

Error 0.2% RDG + 0.02% FS Maximum resolution 0.001ohm

14. PT secondary load measurement: 0 ~ 80kohm (800ohm / 8kohm / 80kohm)

Error 0.2% RDG + 0.02% FS Maximum resolution 0.1ohm

15. Turn ratio measurement: range: 1 ~ 30000, 1 ~ 5000 error <0.2%, 5000 ~ 30000 error <0.5%

16. Number of data storage groups: more than 1000 groups

17. Working conditions: temperature: -10 ℃ ~ 50 ℃, humidity: ≤90%

18. Size: 485mm × 356mm × 183mm

19. Weight: 15Kg

 

ISO9001 AC 220V Variable Frequency CT PT Testing Equipment 0

 

 

OUR SERVICES :

Professional Consulting Services

Detailed Information About Products

Reasonable Price

Welcome Customer Visit

 

 

Signing Contracts And Technical Agreements

Ensure Execution Of Contract And Agreement

Active Communication

Complete After-Sales Service

 

 

Professional After-Sale Service Team

1 Year Free Warranty, Life-Long Maintenance

Help Troubleshooting Within 24 Hours

Professional R & D Team

Multi Functional Single Phase Relay Tester Protection Relay Measurement Equipment 3

Multi Functional Single Phase Relay Tester Protection Relay Measurement Equipment 5

 

 

 

Contact Details
Wuhan GDZX Power Equipment Co., Ltd

Contact Person: Linda

Tel: +8613886061946

Send your inquiry directly to us (0 / 3000)