Wuhan GDZX Power Equipment Co., Ltd sales@gdzxdl.com 86--17362949750
Product Details
Place of Origin: China
Brand Name: GDZX
Certification: ISO
Model Number: ZX-267
Payment & Shipping Terms
Minimum Order Quantity: 1set
Price: USD$500.00-2000/sets
Packaging Details: Packed in wooden case
Delivery Time: 5-10 work days
Payment Terms: L/C,T/T,Western Union,D/P
Supply Ability: 1000sets/ month
Output Voltage: |
(0.00~5.00)kV AC / (0.00~5.00)kV DC |
Max Output Power: |
100VA / 500VA / 1000VA |
Max Rated Current: |
20mA / 100mA / 200mA |
Test Time Range: |
0.0s~999s |
Voltage Accuracy: |
±(5%+3 Words) |
Dimensions: |
450*515*230mm |
Output Voltage: |
(0.00~5.00)kV AC / (0.00~5.00)kV DC |
Max Output Power: |
100VA / 500VA / 1000VA |
Max Rated Current: |
20mA / 100mA / 200mA |
Test Time Range: |
0.0s~999s |
Voltage Accuracy: |
±(5%+3 Words) |
Dimensions: |
450*515*230mm |
This series of high voltage test equipment is a basic-type voltage withstand tester with excellent performance. The output voltage is regulated by a high-reliability, high-durability regulator. A high-brightness LED digital screen displays test time, voltage, and current, with real-time breakdown current and voltage values. The alarm current value is freely preset. Test time is displayed on a three-digit tube with a minimum resolution of 0.1s and a preset range of 0.0s to 999s. Equipped with a signal input/output interface for PLC, the unit can be easily integrated with a PLC-based test system to quickly and accurately measure the dielectric strength of electronic components, household appliances, insulation materials, instruments and meters, lighting appliances, and electric heating appliances.
This series of products meets the following standards:
| Model | AC | DC | ||||
|---|---|---|---|---|---|---|
| 5kV | 10kV | 20kV | 5kV | 10kV | 20kV | |
| ZX2670A | 20mA | — | — | — | — | — |
| ZX2671A | — | 20mA | — | — | 10mA | — |
| ZX2671B | — | 50mA | — | — | 20mA | — |
| ZX2671C | — | 100mA | — | — | 20mA | — |
| ZX2672A | 20mA | — | — | 10mA | — | — |
| ZX2672B | 100mA | — | — | — | — | — |
| Item | ZX2670A | ZX2672A | ZX2672B | ZX2672C | ZX2672D |
|---|---|---|---|---|---|
| ACW Output Voltage Range | (0.00–5.00) kV | ||||
| ACW Maximum Output Power | 100VA (5.000kV/20mA) | 500VA (5.0kV/100mA) | 1000VA (5.0kV/200mA) | ||
| ACW Maximum Rated Current | 20mA | 100mA | 200mA | ||
| ACW Current Stalls | 2mA, 20mA | 2mA, 20mA, 100mA | 2mA, 20mA, 200mA | ||
| Output Waveform | Sine wave | ||||
| Output Waveform Distortion | ≤5% (no-load or pure resistive load) | ||||
| Test Time | 0.0s–999s; 0.0 = continuous test | ||||
| DCW Output Voltage Range | — | (0.00–5) kV | — | (0.00–5.00) kV | |
| DCW Maximum Output Power | — | 50VA (5kV/10mA) | — | 100VA (5.00kV/20mA) | |
| DCW Maximum Rated Current | — | 10mA | — | 20mA | |
| DCW Current Taps | — | 2mA, 10mA | — | 2mA, 20mA | |
| DCW Ripple Factor | — | ≤5% | — | ≤5% | |
| DCW Test Time | — | 0.0s–999s; 0.0 = continuous test | — | 0.0s–999s; 0.0 = continuous test | |
| Voltage (V) Range | (0.00–5.00) kV | ||||
| Voltage Accuracy | ±(5% + 3 words) | ||||
| Voltage Resolution | 10V | ||||
| Voltage Display Value | Root mean square value | ||||
| Current (A) Measuring Range — AC | 0.100mA–20.0mA | 0.100mA–100mA | 0.1mA–200mA | ||
| Current (A) Measuring Range — DC | — | 0.1mA–10.0mA | — | 0.100mA–20.0mA | |
| Current Resolution | 2mA file: 1µA; 20mA file: 10µA; 100mA (200mA) file: 0.1mA | ||||
| Current Measurement Accuracy | ±(5% + 3 words) | ||||
| Timer Range | 0.0s–999s | ||||
| Timer Minimum Resolution | 0.1s | ||||
| Timer Accuracy | ±(1% + 50ms) | ||||
| PLC Interface | Optional | ||||
| Remote Control Interface | Yes | ||||
| Exterior Dimensions | 315 × 285 × 175 mm | 440 × 380 × 180 mm | 430 × 375 × 190 mm | ||
| Weight | 8.76 kg | 9.10 kg | 13.72 kg | 18.2 kg | 24.6 kg |
| Item | ZX2671A | ZX2671B | ZX2671C |
|---|---|---|---|
| ACW Output Voltage Range | (0.00–10.00) kV | ||
| ACW Maximum Output Power | 200VA (10.0kV/20mA) | 500VA (10.0kV/50mA) | 1000VA (10.0kV/100mA) |
| ACW Maximum Rated Current | 20mA | 50mA | 100mA |
| ACW Current Taps | 2mA, 20mA | 2mA, 20mA, 50mA | 2mA, 20mA, 100mA |
| Output Waveform | Sine wave | ||
| Output Waveform Distortion | ≤5% (no-load or pure resistive load) | ||
| Test Time | 0.0s–999s; 0.0 = continuous test | ||
| DCW Output Voltage Range | (0.00–10.0) kV | ||
| DCW Maximum Output Power | 100VA (10.0kV/10mA) | 200VA (10.0kV/20mA) | |
| DCW Maximum Rated Current | 10mA | 20mA | |
| DCW Current Taps | 2mA, 10mA | 2mA, 20mA | |
| DCW Ripple Factor | ≤5% | ||
| DCW Test Time | 0.0s–999s; 0.0 = continuous test | ||
| Voltage (V) Range | (0.00–10.0) kV | ||
| Voltage Accuracy | ±(5% + 3 words) | ||
| Voltage Resolution | 10V | ||
| Voltage Display Value | Root mean square value | ||
| Current (A) Measuring Range — AC | 0.100mA–20.0mA | 0.100mA–50mA | 0.100mA–100mA |
| Current (A) Measuring Range — DC | 0.100mA–10.0mA | 0.100mA–20.0mA | |
| Current Resolution | 2mA stop: 1µA; 20mA stop: 10µA; 50mA (100mA) stop: 0.1mA | ||
| Current Measurement Accuracy | ±(5% + 3 words) | ||
| Timer Range | 0.0s–999s | ||
| Timer Minimum Resolution | 0.1s | ||
| Timer Accuracy | ±(1% + 50ms) | ||
| PLC Interface | Optional | ||
| Remote Control Interface | Yes | ||
| Exterior Dimensions | 380 × 305 × 195 mm | 443 × 390 × 220 mm | 440 × 380 × 180 mm |
| Weight | 14.76 kg | 25 kg | 18.2 kg |