logo

Wuhan GDZX Power Equipment Co., Ltd sales@gdzxdl.com 86--17362949750

Wuhan GDZX Power Equipment Co., Ltd Company Profile
products
Home > products > Transformer Testing Equipment > JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss

Product Details

Place of Origin: Hubei, China

Brand Name: GDZX

Certification: ISO9001

Model Number: JSY-03

Payment & Shipping Terms

Minimum Order Quantity: 1 Set

Price: $2,500.00 - $5,000.00 / Sets

Packaging Details: Carton or wooden box

Delivery Time: 7~10 work days

Payment Terms: L/C,D/A,D/P,T/T

Supply Ability: 100 Set/Sets per Month

Get Best Price
Product Details
Highlight:

transformer test instruments

,

transformer testing machine

Product Name:
Transformer Oil Tan Delta Dielectric Loss Tan Delta Tester
Test Current Range:
10μA-1A
Maximum Output Current:
200mA
Environment Temperature:
-10℃-50℃
Relative Humidity:
<90%
Power:
Electronic
Product Name:
Transformer Oil Tan Delta Dielectric Loss Tan Delta Tester
Test Current Range:
10μA-1A
Maximum Output Current:
200mA
Environment Temperature:
-10℃-50℃
Relative Humidity:
<90%
Power:
Electronic
Product Description


This tester adopts modern technology to achieve automatic frequency conversion, analog-digital conversion and calculation, features strong anti-interference ability, fast test speed, high precision, automation, easy operation. Its high-power switch supply can output 45Hz and 55Hz pure sine wave, boost automatically with voltage up to 10kV. As the power frequency disturbing can be eliminated, it is suitable for field test in power plants or other places with strong electromagnetic interference, now widely used for dielectric Loss factor (tgδ) measurement of transformer, bushing, capacitor, arrester and other equipment.


Features

1. Complex number current method to measure capacitance, tgδ, and other parameters. Auto, High accuracy

2. Reliable measuring data in heavy electromagnetic interference environment

3. Large screen LCD display, menu prompts, easy reading and easy operation
4. Microprocessor control, auto measurement ( after choose measuring methods)

5. Compact structure with standard capacitor and high voltage power supply inside, easy wiring.
6. High accuracy, oil dielectric loss measurement to be done by matching with oil cup and test lines

7. CVT self-excited test function, one time measurement to get C1, C2 capacitance and dielectric loss
8. Grounded specimen test adopts ivddv technology to get stable measurement data
9. Low-voltage shielding function, when 220kV CVT bus is grounded, C11 can be disconnected for 10kV GST

10. HV (+10kV) dielectric loss factor test function ( after match with HV transformer or resonance devices)
11. Grounding protection function, over current protection function

12. Electric shock protection function, auto cut off power when operator accidentally get an electric shock.


Parameters

Accuracy: Cx: ±(reading×1%+1pF), Tgδ: ±(reading×1%+0.00040)

Anti-interference index: within 200%

Capacitance range: Internal HV: 3pF-60000pF/10kV 60pF-1μF/0.5kV

External HV: 3pF-1.5μF/10kV 60pF-30μF/0.5kV

Resolution: Maximum 0.001pF, 4 valid figures.

tgδ range: unlimited, resolution 0.001%, auto identifying specimen to be capacitor, inductor or resistor.

Test current range: 10μA-1A

Internal HV: voltage setting range: 0.5-10kV

Maximum output current: 200mA

Buck-boost method: continuous smooth regulation

Test frequency: 45, 50, 55, 65Hz single frequency, 45/55Hz, 55/65Hz, 47.5/52.5Hz auto dual frequency

External HV: In case of UST, maximum test current: 1A, power frequency or variable frequency 40-70Hz

In case of GST, maximum test current 10kV/1A, power frequency or variable frequency 40-70Hz

CVT self-exciting low voltage output: Output voltage 3-50V, output current 3-30A

Measuring duration: About 40s, depending on measuring method

Input power supply: 180V-270VAC, 50Hz±1%, powered by main supply or generator

Computer interface: Standard RS232 interface

Printer: WH-A7 mini-type thermal printer

Environment temperature: -10℃-50℃, Relative humidity: <90%

Overall dimension:460×360×350mm, weight:28kg

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 0

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 1

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 2

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 3

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 4

Packaging & Shipping

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 5

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 6JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 7JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 8


Packaging & Shipping

(1)We will ship products within 5-20 working days after the receipt of confirmation of your payment.
(2)All products will be well packed by robust carton or wooden box so as to ensure goods can arrive safely.
(3)Multiple shipping methods including express, sea freight, railway and so on for your choice, competitive shipping method will be advised to you.
(4)If you go with your own forwarder, we will provide all necessary documents for customs clearance.
(5)After shipping, we will remain attentive till goods well received.

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 7

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 10

Company Information

Wuhan GDZX Power Equipment Co.,Ltd. is a manufacturer of power test equipmentIntegrating design , production and sales, providing complete solutions for high-voltage testing and electrical testing services for various power users.The main products include:AC series resonance test device, high voltage test equipment, transformer test equipment, secondary protection / switch test equipment, cable fault tester, arrester test equipment, power metering equipment, standard source series and so on. There are many kinds of products and complete models.

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 11

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 12

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 13JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 14JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 15

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 16

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 17


JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 18

Our Services

Service
* Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions.
* Ensure customer get the detailed information about the product in hand.
* Reasonable price, we trust our customers should get the worth what they paid. Quotation stamped and confirmed by Manager.
* Welcome customers visit.
* The contract and the technical agreement to sign by both parties.
* Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements.
* Focus on communication, actively communicate with users, take notes of user’s questions and schedule, provide the necessary technical support.
* Move quick and efficient, professional on delivery, installation, debugging, training and others.
Warranty
* We maintains 100% customer satisfaction, please give us feedback if you fell anything wrong with the product, we will make it right for you.
* Our products are guaranteed with one year warranty and life-long tech support.
* Provide solutions within 24 hours when there is problems feedback from customer.

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 19

JSY-03 Reliable Design Tan Delta Test Of Transformer Oil Tan Delta Dielectric Loss 20




FAQ

1.Q: Are you trading company or manufacturer?
A: We are manufacturer.

We have R&D department, OEM& ODM services available.


2.Q: How long is your delivery time?
A: We usually arrange shipment within 5-7 working days after checking the payment. However, for example, the delivery time of the complete set of test devices will be a little longer, which needs to be checked in real time.


3.Q: Do you provide samples? Is it free or extra?
A: Yes, we could offer the sample, but not for free; you need pay charge and the cost of freight.


4.Q: What is your term of payment?
A: Payment<=5000USD, 100% in advance. Payment>=5000USD, 40% T/T in advance, balance before shipment.


5.Q: What is the payment method?
A: We can accept Bank Transfer, T/T, PayPal, Western Union, Money Gram, Cash etc.


6.Q: Will you provide OEM service?
A: OEM & ODM services available


7.Q: How long is the product warranty?
A: 1 year.