Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output

Product Details

Place of Origin: China

Brand Name: GDZX

Certification: ISO

Model Number: ZXYZ-2002

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: US $ 2677-3999

Packaging Details: Carton or wooden box

Payment Terms: L/C, T/T

Get Best Price
Product Details
Highlight:

2A Transformer Tap Switch Tester

,

AC220V Transformer Tap Switch Tester

Model NO.:
ZXYZ-2002
Specification:
With The Change Of Technical Scheme
Transport Package:
Carton/Wooden Case
Production:
Capacity 500 Pieces/Month
Working Power Supply::
AC220V,50Hz
Sampling Frequency::
10K
Output Current::
1.0A, 0.5A, 0.3A, Three Grades Are Available
Model NO.:
ZXYZ-2002
Specification:
With The Change Of Technical Scheme
Transport Package:
Carton/Wooden Case
Production:
Capacity 500 Pieces/Month
Working Power Supply::
AC220V,50Hz
Sampling Frequency::
10K
Output Current::
1.0A, 0.5A, 0.3A, Three Grades Are Available
Product Description

Product details

 

Multi-Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output

Product Description
ZXYZ-2002 Transformer On Load Tap Switch Tester is mainly used for measuring transformer on-load tap switch transition waveform, transition time, the instantaneous transition resistance value, three-phase synchronization, etc. High degree of intelligent instrument, all Chinese menu prompts, easy to operate. The instrument is small in size, light in weight and strong in anti-interference ability, which greatly reduces the labor intensity of the field staff. It is the ideal instrument for ensuring safe production and improving product quality in the hair and power supply units and transformer manufacturing industry.
Features

1. The output current is large and the weight is light.
2. The instrument output open circuit voltage 28V, in the current of 1A can test 10 ω transition resistance, and has 0.5A, 0.3a, convenient test of large transition resistance.
3. With perfect protection circuit, high reliability.
4. Vertical chassis structure, 5.7 inch large LCD display, easy to operate on site, with printing function.
5. With U disk storage function, can store more data waveform.

 

Technical Indicators

Output current 1.0A, 0.5A, 0.3A, three grades are optional
Resistance range 1.0A range:0.1 ~ 10 Ω
0.5A grade:5 ~ 20 Ω
0.3A grade:10 ~ 40 Ω
Resistance measurement accuracy ±(reading ×5%+5 words), resolution: 0.01 Ω
Measurement range of transition time 1 ~ 250mS
Transition time measurement accuracy ±1mS, resolution: 0.1ms
Sampling frequency 10K
Storage mode U disk storage, local storage
Operating temperature -20ºC ~ +50ºC
Ambient humidity ≤90%RH, no condensation
Power supply AC220V±10%, 50Hz±10%

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 0

 

Packaging & Shipping

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 1

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 2Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 3Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 4

Company Information

Wuhan GDZX Power Equipment Co.,Ltd. is a manufacturer of power test equipment, integrating design, production and sales, providing complete solutions for high-voltage testing and electrical testing services for various power users.The main products include:AC series resonance test device, high voltage test equipment, transformer test equipment, secondary protection / switch test equipment, cable fault tester, arrester test equipment, power metering equipment, standard source series and so on. There are many kinds of products and complete models.

 

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 5

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 6

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 7Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 8

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 9

 

 

 

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 10

 

 

 

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 11

 

 

Customer visit

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 12

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 13

Our Services

 

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 14
 
Customer Feedback

Multi Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output 15