logo

Wuhan GDZX Power Equipment Co., Ltd sales@gdzxdl.com 86--17362949750

Wuhan GDZX Power Equipment Co., Ltd Company Profile
News
Home >

Wuhan GDZX Power Equipment Co., Ltd Company News

Lastest company news about The Critical Role of ZXMD-2001 Fully Automated SF6 Density Relay Calibrator in Modern Power Equipment Maintenance 2025/03/11
The Critical Role of ZXMD-2001 Fully Automated SF6 Density Relay Calibrator in Modern Power Equipment Maintenance
   In the realm of high-voltage power systems, SF6 gas-insulated equipment plays a pivotal role in ensuring operational safety and reliability. As a critical component, SF6 density relays monitor and maintain optimal gas pressure to guarantee insulation and arc-extinguishing performance. However, traditional calibration methods for these relays often face challenges such as environmental dependency, operational complexity, and measurement inaccuracies. The ZXMD-2001 Fully Automated SF6 Density Relay Calibrator emerges as an indispensable tool for technicians, addressing these limitations through advanced automation and intelligent design. Key Technical Advantages 1.Intelligent Temperature-Pressure CompensationLeveraging a 32-bit microprocessor and high-speed signal processing chips, the ZXMD-2001 automatically converts real-time pressure measurements at ambient temperatures to equivalent values at 20°C. This dynamic compensation eliminates the need for temperature-controlled environments, enabling accurate field calibration under varying conditions (-20°C to 80°C). Such capability is vital for maintaining precision in diverse operational settings. 2.High-Precision MeasurementEquipped with a 0.001 MPa resolution pressure sensor and 0.2% accuracy class, the device ensures reliable detection of relay alarm and lockout signals (supporting 1 alarm + 2 lockout configurations). This precision minimizes false tripping risks and enhances grid stability. 3.Streamlined WorkflowThe integration of a 320×240 graphic LCD, rotary navigation dial, and automated test sequences reduces human intervention. Technicians can complete calibration tasks efficiently, with results displayed in real-time and stored locally (50-test capacity) or printed via embedded thermal printer. This workflow optimization significantly cuts downtime during maintenance. 4.Eco-Friendly and Cost-EffectiveBy minimizing SF6 gas consumption during testing, the ZXMD-2001 aligns with environmental regulations while reducing operational costs. Its portable design (8 kg weight, 8-hour battery life) and universal adaptors further support on-site use without disassembling relays, avoiding gas leakage risks. 5.Robust Data ManagementAdvanced features like timestamped data logging, fault auto-diagnosis, and field-adjustable system parameters empower technicians to perform traceable maintenance. The Chinese-language report format enhances readability for regional teams. Technical Superiority in Practice The ZXMD-2001 redefines field calibration by resolving three longstanding industry pain points: 1.Environmental Limitations: Eliminates dependency on climate chambers through real-time temperature compensation. 2.Human Error: Automated pressure regulation and testing sequences ensure repeatable results. 3.Data Fragility: Secure storage with power-loss protection safeguards historical records.  For critical infrastructure such as GIS substations and circuit breakers, this device ensures compliance with IEC 62271-203 standards by maintaining relay accuracy within ±1% of setpoints. Its ability to test multiple relay types (single/double lockout, single alarm, etc.) makes it a versatile solution for modern power networks. Conclusion     As power systems increasingly adopt SF6-based equipment, the ZXMD-2001 stands as a technological cornerstone for predictive maintenance strategies. By combining laboratory-grade accuracy with rugged portability, it empowers technicians to preempt insulation failures, optimize asset lifecycle management, and uphold grid reliability. Its role extends beyond mere calibration—it is an essential enabler of safe, sustainable, and efficient power system operations in the digital age.    GDZX is a manufacturer of power testing equipment, offering a wide range of product categories with comprehensive models and providing professional technical support. Contact: +86-17396104357. Website: https://www.highvoltage-testequipment.com/
Read More
Lastest company news about FZY-3 Stray Current Comprehensive Tester: Industry and Technical Perspectives 2025/03/10
FZY-3 Stray Current Comprehensive Tester: Industry and Technical Perspectives
Industry Perspective: Enhancing Safety in Critical Environments 1. Addressing Industrial Challenges   In high-risk industrial settings such as coal mines, rail transit systems, and underground pipelines, stray currents pose significant threats to operational safety. These currents can accelerate electrochemical corrosion of metal structures, trigger premature detonation of electric detonators, or ignite flammable gases like methane. The FZY-3 Stray Current Comprehensive Tester is engineered to mitigate these risks by providing precise detection and monitoring capabilities tailored for harsh environments. 2. Market Positioning and Competitive Advantages Wide Measurement Range: With 20 selectable ranges (0.2V–40V for voltage, 50mA–10A for current), the FZY-3 outperforms conventional testers in detecting both AC/DC stray currents across diverse conductors, including rails, cables, and pipelines. Intrinsic Safety: As a self-powered device requiring no external power source, it eliminates explosion risks associated with battery-operated tools, complying with GB 3836-2010 standards for explosive atmospheres. Cost Efficiency: Its compact, maintenance-free design reduces ownership costs by 60% compared to imported alternatives, democratizing access to advanced safety testing in resource-intensive industries. 3. Regulatory Compliance and Future Trends   Global regulations, such as the International Electrotechnical Commission (IEC) Standard for Mine Safety, increasingly mandate strict stray current management. The FZY-3 aligns with these requirements while offering scalability for integration with IoT-enabled mining systems, positioning it as a cornerstone of modern industrial safety infrastructure. Technical Deep Dive: Design and Operation 1. Core Technical Specifications Measurement Accuracy: DC Voltage/Current: ±2.5% AC Voltage/Current: ±5% Ranges: Voltage: 0–0.2V, 1V, 4V, 20V, 40V Current: 0–50mA, 250mA, 1A, 5A, 10A Safety: Overload protection via fused circuits (5A/250V rating). 2. Innovative Design Features Dual-Mode Detection: Employs a hybrid shunt-Transformer circuit to isolate AC/DC measurements, minimizing cross-interference. Mechanical zero-adjustment ensures baseline stability without electronic drift. Portability: Weighing 80% conductor centering within the clamp to maintain accuracy. In multi-grounded systems, adopt grid-based measurement points to map equipotential zones. 4. Limitations and Upgrade Pathways Current Limitations: Manual range switching and lack of data logging. Proposed Enhancements: Integrate Bluetooth/Wi-Fi for real-time data transmission to mobile devices. Develop IP67-rated variants for use in high-humidity or dusty environments. Case Study: Field Performance in Coal Mines       A coal mine in Shanxi, China, reported a 40% reduction in stray current-related incidents after deploying FZY-3 testers for monthly inspections. Key outcomes included: Early detection of 15V DC stray voltage on conveyor rail joints, preventing potential spark risks. Identification of unbalanced currents (3.2A AC) in power cable screens, prompting timely grid adjustments. Comparative Analysis with Competing Models   Parameter Model X (International) FZY-3 Advantage AC/DC Range DC only AC/DC dual-mode + Versatility Explosion Rating Ex ib IIB Ex ia I + Safety Level Portability 2.8 kg 1.4 kg +43% lighter Cost (USD) $6,500 $2,200 -66% savings   Conclusion      The FZY-3 Stray Current Comprehensive Tester exemplifies China’s advancements in industrial safety technology, combining precision, reliability, and cost-effectiveness. For global industries grappling with stray current hazards, this device offers a robust solution that aligns with both regulatory mandates and operational efficiency goals. Future iterations focusing on digital integration and environmental resilience will further solidify its role in smart industrial ecosystems.      GDZX is a manufacturer of power testing equipment, offering a wide range of product categories with comprehensive models and providing professional technical support. Contact: +86-17396104357. Website:https://www.highvoltage-testequipment.com/    
Read More
Lastest company news about Significance of the GM-5kV Adjustable High Voltage Digital Megohmmeter 2025/03/07
Significance of the GM-5kV Adjustable High Voltage Digital Megohmmeter
The GM-5kV Adjustable High-Voltage Digital Megohmmeter, developed by Guodian Zhongxing, is a cutting-edge instrument designed for precision insulation resistance testing in high-voltage power systems. Tailored for challenging environments such as substations, power plants, and remote cable networks, this device ensures reliable performance under strong electromagnetic interference (EMI) and high-voltage leakage conditions. Its advanced features and robust design make it indispensable for evaluating the insulation integrity of transformers, motors, generators, and long-distance power cables.   Key Performance Features Intelligent Control & User Interface Microprocessor-controlled operation with menu-driven navigation. Large LCD dot-matrix display for real-time data visualization. Combined analog bar graph and digital readout for dynamic trend analysis. High-Voltage Output Flexibility Seven preset voltage levels: 50V, 100V, 250V, 500V, 1.0kV, 2.5kV, and 5.0kV. Continuously adjustable output from 0V to 5kV for customized testing requirements. Advanced Measurement Capabilities Insulation Resistance (IR): Measures 0–10 TΩ with auto-ranging. Time-Stamped Metrics: Automatically calculates R15, R60, R600, absorption ratio (DAR), and polarization index (PI). Multi-Parameter Detection: Simultaneously displays leakage current (0.1nA–9.9mA) and absorption capacitance (0.1pF–99μF). Enhanced Safety & Reliability Pre-test live circuit detection with voltage alerts. Auto-discharge function (
Read More
Lastest company news about Core Value and Application Analysis of GM-2500V Adjustable High-Voltage Digital Megohmmeter inPower EquipmentMaintenance 2025/03/06
Core Value and Application Analysis of GM-2500V Adjustable High-Voltage Digital Megohmmeter inPower EquipmentMaintenance
       In power systems, the insulation performance of electrical equipment directly impacts grid safety and reliability. As power equipment evolves toward higher voltages and complexity, traditional insulation resistance testers struggle to meet the demands for accurate measurements in environments with strong electromagnetic interference. The GM-2500V Adjustable High-Voltage Digital Megohmmeter, designed for high-voltage substations, power plants, and other complex scenarios, has become an essential tool for diagnosing insulation performance due to its high precision, robust anti-interference capabilities, and multifunctionality. This paper delves into the technical features, application scenarios, and practical value of this device in power equipment maintenance. I. Technological Breakthroughs in High-Voltage Complex Environments Adjustable High-Voltage Output and Wide Measurement RangeThe GM-2500V offers four adjustable voltage outputs (250V, 500V, 1kV, 2.5kV) with continuous zero-start adjustment, enabling precise adaptation to equipment of varying voltage levels. Its measurement range spans 0.1MΩ to 5TΩ, suitable for scenarios from low-voltage distribution systems to high-voltage transformers and long-distance power cables. For example, the 2.5kV mode effectively detects deep insulation defects in equipment rated ≥110kV, avoiding missed judgments caused by insufficient voltage in traditional devices. High Precision and Anti-Interference CapabilitiesIn environments with strong electromagnetic interference (e.g., power plants, substations), traditional megohmmeters are prone to data distortion due to power frequency leakage or induced voltages. The GM-2500V employs microcomputer control and digital filtering technology, coupled with a lower-range accuracy of ±(5%·Rx +1d), ensuring stable voltage output and reliable data acquisition even under interference. Its 5mA short-circuit current design penetrates surface contaminants to reflect the true volume resistance of insulation materials. Dynamic Insulation AnalysisThe device automatically calculates absorption ratios (R60/R15) and polarization indices (R600/R60), providing quantitative assessments of insulation moisture ingress or aging. For instance, an absorption ratio 1 minute. Field Operation Standards Ensure reliable grounding (resistance ≤4Ω) before testing to prevent residual charge accidents. Use a "guard ring" to eliminate surface leakage currents during cable measurements. Data Interpretation Polarization index >2.0 indicates dry, healthy insulation; 30% suggest localized insulation damage.     The GM-2500V addresses insulation testing challenges in high-voltage, high-interference environments through technological innovation. Its high precision, intelligent analysis, and safety features enhance equipment condition assessment reliability and drive the shift from scheduled to condition-based maintenance. Proficiency in this tool empowers technicians to improve fault prediction, laying a foundation for smart grid preventive maintenance systems.     GDZX is a manufacturer of power testing equipment, offering a wide range of product categories with comprehensive models and providing professional technical support. Contact: +86-17396104357. Website: https://www.highvoltage-testequipment.com/
Read More
Lastest company news about Technical principles and engineering application analysis of ZXBXZ series series resonant voltage withstand device 2025/03/05
Technical principles and engineering application analysis of ZXBXZ series series resonant voltage withstand device
1. Introduction In the field of high-voltage testing of power systems, traditional power frequency voltage withstand equipment is difficult to meet the high-precision testing needs of modern substation equipment due to problems such as huge volume and output waveform distortion. The ZXBXZ series series resonant voltage withstand voltage devices are based on the LC resonance principle, and can realize efficient and accurate AC voltage withstand voltage tests through intelligent frequency conversion technology, which is especially suitable for preventive tests and handover tests of primary equipment of 10kV~500kV substations. This article analyzes technical principles, system architecture, engineering selection and typical application scenarios, and provides systematic reference for technicians.   2. Key technical parameters model Rated capacity Output voltage Applicable scenarios Reactor configuration ZXBXZ-50 50kva 50kV 10kV transformer ( ≤1000kVA ), 1km cable 2×25kV dry type ZXBXZ-270 270kva 270kv 110kV GIS equipment, 3km cable 6×45kV dry type ZXBXZ-1600 1600kva 00kV 500kV GIS , 220kV cable 4×200kV oil immersion   3. Typical engineering application solutions 110kV GIS equipment AC voltage test Test parameters: voltage 185kV ( 1.2U  m ), frequency 45~300Hz , time 1min Configuration plan: a. Select ZXBXZ-270 model, 6×45kV reactor connected in parallel b. Frequency tuning to the test capacitor resonance point (typical value is about 70Hz ) c. Set the overcurrent protection threshold ≤100mA   4. Key technologies and fault handling on-site operation 1. Optimization of operation process Automatic mode: Set the target voltage → Automatic frequency sweep (step 0.1Hz ) → Lock the resonance point → Boost to set value (slope ≤1kV/s ) Manual mode: You need to monitor the Q value changes to avoid frequency deviation from the resonant point and cause overcurrent (recommended use when Q value > 30 )   2. Common fault diagnosis Fault phenomenon Possible Causes Solution Can't resonate Test capacitor is too small / too large Adjust the reactor series and parallel connection method Output waveform distortion Grid harmonic interference Enable power filtering Protect frequently Test sample partial discharge Check the insulation of the test sample to reduce the boost rate   5. Technological innovation and industry value 1. Dry reactor technology: adopts vacuum epoxy casting technology, compared with traditional oil-immersed equipment: 40% reduction in volume and 35% reduction in weight No oil leakage risk, suitable for mobile test scenarios 2. Intelligent protection system: Flash protection response time 
Read More
Lastest company news about The Critical Role of ZXQ Discharge Protection Sphere Gap Tester in Modern Electrical Systems 2025/03/03
The Critical Role of ZXQ Discharge Protection Sphere Gap Tester in Modern Electrical Systems
    In the rapidly evolving field of electrical engineering, ensuring the safety and reliability of high-voltage systems is paramount. The ZXQ Discharge Protection Sphere Gap Tester emerges as an indispensable tool in this context. Designed for precision, durability, and ease of use, this device plays a pivotal role in high-voltage testing, insulation coordination, and overvoltage protection across diverse industrial applications.    Key Features of the ZXQ Sphere Gap Tester    High-Voltage Testing and Protection   The ZXQ tester is engineered to evaluate voltage withstand capabilities and discharge characteristics of insulating materials. By simulating real-world overvoltage conditions, it ensures that electrical components meet stringent safety standards, preventing catastrophic failures in transformers, switchgear, and transmission lines.    Compact and Portable Design   Unlike traditional bulky testing equipment, the ZXQ series boasts a lightweight, space-saving structure. Its portability enables on-site testing in remote locations, reducing downtime and operational costs. Versatile Installation OptionsWith support for both vertical and horizontal configurations, the device adapts to varied testing environments, from laboratory setups to field installations.    Technical Specifications    Models: Q-50KV, Q-100KV, Q-150KV, Q-200KV    Sphere Diameters: φ50mm, φ100mm, φ150mm, φ200mm    Compatibility: Integrates seamlessly with high-voltage test transformers, control consoles, and voltage regulators. Environmental Resilience: Waterproof construction ensures reliable performance in harsh conditions.    Why the ZXQ Tester is Indispensable    Enhanced Safety Protocols   By accurately measuring breakdown voltages and discharge gaps, the ZXQ tester identifies insulation weaknesses before they escalate into hazards. This proactive approach safeguards personnel and equipment from arc flashes and electrical fires.    Compliance with International Standards   The device aligns with IEC and IEEE guidelines for high-voltage testing, making it a trusted choice for utilities, manufacturers, and certification bodies.    Cost-Efficiency   Its modular design allows users to select sphere diameters (φ50–φ200mm) and voltage ratings (50–200KV) tailored to specific needs, eliminating the expense of over-specified equipment.    Operational Flexibility   The combination of vertical/horizontal installation and rapid deployment capabilities makes it ideal for emergency fault diagnosis and routine maintenance in power grids, renewable energy systems, and industrial plants.     The ZXQ Discharge Protection Sphere Gap Tester represents a convergence of innovation and practicality in high-voltage testing. As electrical systems grow more complex, this device ensures operational resilience, regulatory compliance, and long-term cost savings. By investing in such advanced diagnostic tools, industries can mitigate risks, optimize performance, and uphold the highest standards of electrical safety in an increasingly electrified world. This article highlights the ZXQ tester's technical merits while emphasizing its strategic importance in modern power infrastructure. The title balances specificity and impact to appeal to engineers, safety officers, and decision-makers in the energy sector.    GDZX is a manufacturer of power testing equipment, offering a wide range of product categories with comprehensive models and providing professional technical support. Contact: +86-17396104357.Website: https://www.highvoltage-testequipment.com/
Read More
Lastest company news about Application and Technical Guide for GM-5KV Adjustable High-Voltage Digital Megohmmeter in Power Equipment 2025/02/26
Application and Technical Guide for GM-5KV Adjustable High-Voltage Digital Megohmmeter in Power Equipment
Introduction     The GM-5KV Adjustable High-Voltage Digital Megohmmeter is a cutting-edge instrument designed for measuring insulation resistance in high-voltage electrical systems. With its robust performance, wide measurement range, and advanced safety features, it is an indispensable tool for industries requiring precise insulation diagnostics, such as power utilities, industrial maintenance, telecommunications, and railway systems. This guide explores its applications, technical specifications, and key features to help users maximize its potential. Key Applications 1.High-Voltage Transformers and Motors Evaluates insulation integrity under high-stress conditions, detecting degradation caused by moisture, contamination, or aging. 2.Underground and Long-Distance Cables Identifies insulation faults in buried or remote cables, ensuring reliability in power transmission and distribution networks. 3.Industrial Equipment Maintenance Tests insulation resistance of switchgear, circuit breakers, and rotating machinery to prevent unexpected failures. 4.Renewable Energy Systems Monitors insulation performance in solar PV arrays, wind turbines, and energy storage systems exposed to harsh environments. 5.Safety Compliance Testing Validates insulation standards (e.g., IEEE, IEC) for electrical installations, ensuring personnel and equipment safety. Technical Specifications 1.Rated Test Voltages: 50V, 100V, 250V, 500V, 1.0kV, 2.5kV, 5.0kV (adjustable). 2.Measurement Range: 0–10 TΩ (auto-ranging). 3.Output Voltage Accuracy: ±5%. 4.Short-Circuit Current: ~5 mA (enhanced load capacity). 5.Basic Measurement Errors: First Half Range: ±(5%·Rx + 1 digit). Second Half Range: ±(10%·Rx + 2 digits). 6.High-Voltage Display Error: ±(5%·Ux + 1 digit). 7.Power Supply: 14.8V lithium battery (30-day runtime with 10 DAR tests and 5 PI tests daily). 8.Insulation Resistance: >500 MΩ (between test leads and case). 9.Environmental Tolerance: Operating: 0°C to +40°C, ≤85% RH. Storage: -20°C to +50°C, ≤90% RH. 10.Safety Compliance: AC 10.0kV/50Hz withstand voltage for 1 minute (case and test leads). 11.Dimensions/Weight: 320×230×270 mm, 4.5 kg. Core Features and Advantages 1.Advanced Measurement Capabilities Automated Calculations: Auto-computes Dielectric Absorption Ratio (DAR) and Polarization Index (PI) by measuring R15s, R60s, and R600s. Wide Voltage Range: Adjustable output from 50V to 5kV for diverse testing scenarios. High Precision: ±5% voltage accuracy and 10 TΩ range ensure reliable diagnostics. 2.User-Centric Design Intuitive Interface: Menu-driven operation with a backlit LCD and analog bar graph for dual-display clarity. Data Logging: Stores up to 60 test records (non-volatile memory retains data for 20 years). Environmental Monitoring: Built-in sensors track temperature, humidity, date, and time. 3.Safety and Reliability Auto-Discharge: Releases residual voltage within 30 seconds post-test. Anti-Interference: Performs accurately in high electromagnetic interference (EMI) environments. Protection Mechanisms: Overload alerts, 5mA short-circuit current limit, and IP-rated insulation. 4.Efficiency and Connectivity Battery Optimization: 30-day operation on a single charge with auto-shutdown after 5 minutes of inactivity. RS232 Interface: Enables data transfer to PCs for analysis and reporting. Operational Guidelines 1.Pre-Test Preparations Ensure equipment is de-energized and properly grounded. Verify test leads and environment meet safety requirements (humidity
Read More
Lastest company news about 1500VA Microcomputer for Petroleum Underwater Rust and Corrosion Analyzer: A Key Tool for Petroleum Quality Assessment 2025/02/25
1500VA Microcomputer for Petroleum Underwater Rust and Corrosion Analyzer: A Key Tool for Petroleum Quality Assessment
Introduction The ZX-XFS Rust and Corrosion Analyzer is a specialized instrument designed in compliance with the Chinese national standard GB/T11143-89 (Test Method for Rust-Preventing Characteristics of Inhibitor-Containing Mineral Oils in the Presence of Water). This advanced equipment is engineered to evaluate the rust-inhibiting performance of mineral oils, particularly turbine oils, when mixed with water. It is also applicable for testing hydraulic fluids, circulating oils, and other liquids denser than water. Widely utilized in petroleum refineries, power plants, and research institutions, the ZX-XFS serves as an indispensable tool for oil quality analysis and industrial compliance. Key Features User-Friendly Interface: Equipped with a blue LCD screen and intuitive Chinese menu navigation, the analyzer ensures straightforward operation through clearly labeled keys. Precision Control: A microprocessor enables automated temperature regulation (±0.5°C accuracy) and programmable timing (0–100 hours), ensuring highly repeatable test conditions. Quiet and Efficient Operation: Four independent stirring motors operate at 1,000 ±25 rpm, delivering consistent agitation without noise interference. Compact Design: Its space-saving structure makes it ideal for laboratory and industrial environments. Technical Specifications Temperature Range: Ambient temperature to 100°C Temperature Accuracy: ±0.5°C Stirring Speed: 1,000 ±25 rpm Test Capacity: 4 independent test chambers Timer Range: 0–100 hours (user-configurable) Ambient Conditions: 0–45°C temperature, ≤85% humidity Power Supply: AC 220V/50Hz, 1,500VA ApplicationsThe ZX-XFS analyzer is critical for: Assessing the anti-corrosion efficacy of turbine oils under water-contaminated conditions. Evaluating hydraulic fluids and industrial lubricants in simulated operational environments. Conducting R&D for oil formulations requiring enhanced rust inhibition. Operational Workflow Sample Preparation: Steel Rod Polishing: Test steel rods are meticulously polished using 240-grit alumina abrasive cloth to achieve a uniform, scratch-free surface. Contamination is avoided by handling rods with tweezers or lint-free cloths. Media Preparation: The bath is filled with a viscosity-controlled medium oil (40°C kinematic viscosity: 28.8–35.2 mm²/s). Test Execution: Method A (Distilled Water): 300 mL of oil sample is mixed with 30 mL distilled water at 60±1°C for 24 hours under continuous stirring. Method B (Synthetic Seawater): Replaces distilled water with synthetic seawater, formulated per specified ionic concentrations (e.g., NaCl, MgCl₂). Method C (Dense Liquids): Incorporates an auxiliary stirring blade to ensure homogenous mixing of water and high-density test liquids. Post-Test Evaluation: Steel rods are inspected under 650 lux illumination without magnification. Corrosion severity is classified as: Mild: ≤6 rust spots (each ≤1 mm diameter). Moderate: >6 spots but 5% surface area corroded. Results are determined via duplicate testing: A "pass" requires both rods to remain corrosion-free. Discrepant outcomes necessitate retesting. Advantages in IndustryThe ZX-XFS analyzer enhances quality control by simulating real-world conditions where oil-water coexistence threatens equipment longevity. Its ability to quantify rust prevention under standardized parameters supports compliance with international oil performance benchmarks, reducing downtime and maintenance costs in critical infrastructure.Conclusion As a cornerstone of oil analysis, the ZX-XFS Rust and Corrosion Analyzer combines precision, versatility, and reliability, making it essential for industries prioritizing equipment protection and operational efficiency. By adhering to GB/T11143-89 and accommodating diverse testing methodologies, it empowers users to deliver oils that meet rigorous anti-corrosion standards. Note: Test reports must specify the method employed (A, B, or C) and the liquid medium (e.g., synthetic seawater in Method B). Regular calibration of steel rods and adherence to procedural guidelines ensure result accuracy.
Read More
Lastest company news about Working Principle and Testing Advantages of ZXR-20A+ Three-Channel DC Resistance Tester 2025/02/24
Working Principle and Testing Advantages of ZXR-20A+ Three-Channel DC Resistance Tester
1. Introduction The ZXR-20A+ Three-Channel DC Resistance Tester is an essential instrument for various tests related to transformers, such as semi-finished and finished product factory tests, installation, handover tests, and preventive tests in the power sector. It can effectively detect manufacturing defects in transformer coils, including material selection, welding issues, loose connection parts, strand shortages, and open circuits, as well as potential hidden dangers during operation. 2. Working Principle 2.1 Current Output and Selection The tester can output different currents according to the requirements of the tested product. For three-phase testing, it offers current combinations of 10A + 10A, 5A + 5A, and 1A + 1A. For single-phase testing, the available current values are 20A, 10A, 5A, 1A, and 200mA. The instrument selects the appropriate current based on the characteristics of the tested object to ensure accurate measurement. 2.2 Measurement of Resistance When conducting measurements, the tester uses independent three-channel current sampling and voltage sampling methods. For star-connected windings, it can measure three-phase resistances simultaneously through the three-channel test function. For YN, D(Y) connected transformers, it can also perform single-phase measurements. The instrument calculates the resistance value by measuring the current flowing through the winding and the voltage across it, using Ohm's law (R = U / I). 2.3 Special Testing Methods for Large Transformers For large transformers with five-column cores and low-voltage windings in a delta connection, the tester adopts a high-low voltage series excitation method. The instrument automatically connects the magnetizing circuit of the windings internally. This method can quickly and accurately measure the DC resistance of the low-voltage windings. 2.4 Data Processing and Display The tester is equipped with a built-in microprocessor that processes the measured data. It can calculate the three-phase resistance unbalance rate when performing three-phase measurements. The measurement results, including resistance values, unbalance rates, and other relevant data, are clearly displayed on a 7-inch color touch screen. The display not only shows the real-time test data but also provides an intuitive and user-friendly operation interface. 3. Testing Advantages 3.1 Time-Saving Three-Channel Simultaneous Measurement: The three-channel test function allows for one-time wiring to complete the measurement of three-phase DC resistances for star-connected windings. This significantly reduces the measurement time compared to traditional single-channel measurement methods. For example, when testing a three-phase transformer, the traditional method may require multiple measurements for each phase, while this instrument can complete all three-phase measurements at once, saving a great deal of time and improving work efficiency. Quick Testing for Large Transformers: For large transformers with complex winding structures, such as those with five-column cores and low-voltage windings in a delta connection, the high-low voltage series excitation method enables fast and accurate measurement of the low-voltage winding resistance. This effectively solves the problem of long testing times for these types of transformers. 3.2 High Accuracy Precise Current Output: The tester can output accurate currents within a wide range, ensuring that the measured resistance values are reliable. The specified current accuracy and stability contribute to the precision of the measurement results. Advanced Sampling and Calculation: The independent three-channel current and voltage sampling techniques, combined with accurate data processing algorithms, enable the instrument to measure resistance values with high precision. The accuracy of the instrument is ±(0.2% + 2 digits), and the minimum resolution is 0.1μΩ, which can meet the high-precision measurement requirements of various applications. 3.3 Versatility Multiple Winding Connection Types: The instrument can handle various winding connection types, including star (YN) and delta (D or Y) connections. It can perform both three-phase simultaneous measurements and single-phase measurements, adapting to different testing needs of transformers with different connection methods. Applicable to Multiple Inductive Resistors: In addition to transformers, the tester is also suitable for measuring the resistance of other inductive components such as mutual inductors, meeting the diverse testing requirements in the electrical field. 3.4 User-Friendly Operation 7-Inch Color Touch Screen: The 7-inch color touch screen provides a clear and beautiful interface display. The intuitive operation menu allows users to easily set parameters, start tests, and view test data. Real-time display of test data enables users to monitor the measurement process and results at any time. Optional Language Interfaces: The instrument offers both Chinese and English operation interfaces, which can be configured according to customer requirements. This makes it convenient for users in different regions to operate the instrument. 3.5 Data Management and Communication Data Storage and Retrieval: The built-in calendar clock and the ability to store, retrieve, and print 100 groups of test data provide convenience for data management. Users can easily access historical test data for analysis and comparison. Communication Interfaces: With RS232 and USB interfaces, the tester can communicate with upper computer control software. The RS232 interface can transfer test data to the background for further analysis and management, while the USB interface allows users to transfer test data to a U disk for easy storage and sharing. 3.6 Protection and Durability Perfect Protection Circuit: The instrument is equipped with a perfect protection circuit, which can effectively protect against various potential problems such as back EMF, disconnection, and power failure. This ensures the safety and reliability of the instrument during operation and reduces the risk of damage to the instrument. Industrial Plastic Shell: The industrial plastic shell not only makes the instrument easy to carry but also improves its service life. It can withstand certain impacts and environmental challenges, ensuring stable performance in different working conditions. In conclusion, the ZXR-20A+ Three-Channel DC Resistance Tester combines advanced working principles and multiple testing advantages, making it an ideal choice for accurately and efficiently measuring the DC resistance of transformers and other inductive components.
Read More
Lastest company news about The Importance of ZX-1200 Microcomputer Relay Protection Tester in Relay Protection 2025/02/21
The Importance of ZX-1200 Microcomputer Relay Protection Tester in Relay Protection
In modern power systems, relay protection plays a crucial role. It is a key line of defense to ensure the safe, stable, and reliable operation of the power system. And the ZX-1200 microcomputer relay protection tester, as an important device in the field of relay protection, is of great significance.   The output part of the ZX-1200 microcomputer relay protection tester is controlled by a DSP, which endows it with many advantages. The DSP has the capabilities of fast operation and powerful real-time digital signal processing. Coupled with a wide transmission band and high-resolution D/A conversion, it enables the output waveform to have extremely high precision, low distortion, and good linearity. This characteristic is of great significance in relay protection because an accurate output waveform can more accurately simulate various fault conditions in the power system, providing a reliable basis for the testing of relay protection devices. For example, when simulating a short-circuit fault, the precise current and voltage output can enable the relay protection device to accurately determine the type and location of the fault, and thus take timely protective actions to prevent the expansion of the fault range.   The tester adopts advanced technologies in its design, selects precise components and materials, and conducts special structural design, achieving the characteristics of small size, light weight, complete functions, and easy portability. This allows it to conveniently carry out work in various complex field environments. Whether it is the daily maintenance of a substation or the overhaul of a power line, it can conduct process tests anytime and anywhere, greatly improving the efficiency and flexibility of relay protection work.   From its characteristics, the miscombination function of the voltage and current output can simulate a variety of complex operation states and fault conditions of the power system, comprehensively testing the action accuracy and reliability of the relay protection device under different working conditions. The new Hi-Fi linear power amplifier and high-performance characteristics ensure that the tester can output stable and high-quality signals, meeting the requirements for high-precision testing of relay protection devices. The software functions for power supply further enhance its convenience and intelligence. Operators can flexibly set various test parameters through the software to adapt to the testing needs of different types of relay protection devices. The independent DC power output and complete interface provide more convenience for the use of the tester in different scenarios, enabling it to better work in coordination with other devices. The perfect self-protection function ensures the safe and stable operation of the tester in a complex testing environment, avoiding damage to the device due to misoperation or external interference.   In terms of technical indicators, the ZX-1200 microcomputer relay protection tester also performs excellently. The standard six-stage current and voltage channel numbers can meet the testing requirements for the multi-phase operation state of the power system. Its AC current output range is from 30A/phase to 180A (six phases in parallel), the DC current output range is 10A DC/phase, the AC voltage output range can reach 120V AC/phase, and the DC voltage output range is 160V DC/phase. Such a wide output range can cover various common current and voltage values in the power system, and it can easily handle the parameter simulation in both normal operation and fault states. For example, when testing the relay protection device of a large-capacity power transformer, a large current output is required to simulate the large current situation inside the transformer during a fault. The ZX-1200 tester can stably output the required current value to ensure the accurate testing of the protection device.   The AC current output has precise accuracy and output power indicators under different working conditions. For example, the output accuracy of the six-phase current output from 0 to 30A reaches the 0.1 level, and the maximum output power of the phase current is 450VA, etc. This ensures that during the testing process, an accurate current signal can be provided for the relay protection device, allowing the protection device to be tested under conditions close to actual operation, thereby improving the reliability of the test results. Similarly, the AC voltage output, DC current output, and DC voltage output all have strict accuracy and output power standards. These indicators jointly ensure that the tester can provide comprehensive and accurate test signals for the relay protection device.   In terms of input and output, there are 8 channels for input and 4 channels for output, which are matched with different input and output parameters, such as free contact 1-20mA, 24V, potential contact "0": 0 +6V; "1": +11V +250V, DC: 220V/0.2A, AC: 220V/0.5A, etc., enabling the tester to effectively connect and interact with various relay protection devices and other related equipment. The time measurement range is 0.1ms to 9999S, and the measurement accuracy is less than 0.1ms, which can accurately measure the action time of the relay protection device. This is crucial for evaluating the performance of the protection device. The fast and accurate action time is one of the key factors for whether the relay protection device can promptly cut off the fault and ensure the safety of the power system.   In conclusion, the ZX-1200 microcomputer relay protection tester, with its advanced technology, excellent performance characteristics, and comprehensive technical indicators, plays an irreplaceable and important role in relay protection work. It provides strong support for the accurate testing, performance evaluation, and daily maintenance of relay protection devices, and is an important tool to ensure the safe and stable operation of the power system. By using the ZX-1200 tester, problems existing in the relay protection device can be discovered in a timely manner, ensuring that it can act quickly and accurately when a fault occurs in the power system. This can effectively avoid power outages, reduce economic losses, and ensure the normal operation of social production and life.
Read More
Lastest company news about Understanding the Boiling and Freezing Points of Oils: Key Insights for Engineers and Buyers 2024/12/03
Understanding the Boiling and Freezing Points of Oils: Key Insights for Engineers and Buyers
Oils play a crucial role across various industries, including electrical engineering, transportation, and food production. Understanding the boiling and freezing points of different types of oils is essential for selecting the appropriate oil for specific applications. This guide provides a comprehensive explanation tailored for new engineers and procurement professionals. Boiling Point of Oils The boiling point of oil refers to the temperature at which the oil transitions from liquid to vapor under standard atmospheric pressure. The boiling points vary significantly depending on the type of oil and its composition. Here are the boiling points for different types of oils: Edible Oils: The boiling point of most edible oils exceeds 200°C. At temperatures beyond 250°C, harmful substances such as butadiene aldehydes may form, posing serious health risks, including the potential for carcinogenic effects. Key Consideration: Avoid overheating edible oils during cooking to prevent the formation of harmful compounds. Gasoline: The boiling point, often referred to as the distillation range, is between 30°C and 205°C. This wide range corresponds to the varying compositions of hydrocarbons within gasoline. Diesel: Diesel has two distinct boiling ranges depending on its grade: Light diesel: 180°C to 370°C. Heavy diesel: 350°C to 410°C. The variation in boiling points reflects the differing molecular weights and compositions of hydrocarbons in diesel fuels. Freezing Point of Oils The freezing point of oil is the temperature at which the oil transitions from a liquid to a solid state. For many oils, particularly those used in industrial and automotive applications, freezing points influence their usability in colder climates. Below are the freezing points for various types of oils: Edible Oils: Extra Virgin Palm Oil, Olive Oil, and Peanut Oil: Freeze at approximately 5°C. Soybean Oil: Freezing point is -8°C. Blended Oils: Freezing points vary based on the composition, typically between 2°C and 13°C. Gasoline: Freezing point: Approximately -75°C, which ensures it remains liquid even in extremely cold environments. Diesel Fuel: Diesel does not have a traditional freezing point but rather a condensation point, where wax crystals form, causing the fuel to gel and impede flow. Condensation points for different diesel grades are as follows: No. 10 Diesel: -5°C. Other Grades: Grade 10: 12°C. Grade 5: 8°C. Grade 0: 4°C. Grade -20: -14°C. Grade -35: -29°C. Grade -50: -44°C. Key Consideration: For operations in colder climates, select a diesel grade with a condensation point lower than the ambient temperature. Why Boiling and Freezing Points Matter in Engineering and Procurement Operational Efficiency: Selecting oils with appropriate boiling and freezing points ensures optimal performance in specific operating environments. For example, in cold climates, oils with low freezing points prevent system blockages, while high boiling points prevent degradation at elevated temperatures. Safety: In electrical systems, transformer oils with stable boiling and freezing points help maintain insulation performance and reduce fire risks under fluctuating temperature conditions. Longevity and Reliability: Using the right oil prevents thermal decomposition or solidification, which can lead to equipment wear and operational inefficiencies. Industry Standards: Many industries, including power generation and automotive, mandate the use of oils that comply with specified temperature characteristics to ensure safety and performance. Conclusion Understanding the boiling and freezing points of various oils is crucial for their effective use in industrial, automotive, and electrical applications. By considering these temperature characteristics, engineers and buyers can make informed decisions, ensuring safety, reliability, and compliance with industry standards. This knowledge also minimizes risks and improves the longevity of systems that rely on oil as a functional medium.
Read More
Lastest company news about Classification of DC High-Voltage Generators by Inverter Frequency: A Comprehensive Guide 2024/12/02
Classification of DC High-Voltage Generators by Inverter Frequency: A Comprehensive Guide
DC high-voltage generators are essential tools in various applications, including X-ray imaging, insulation testing, and high-voltage equipment evaluation. These generators can be classified into three categories based on their inverter frequency: power frequency, intermediate frequency, and high-frequency high-voltage generators. Each category has distinct characteristics, advantages, and limitations that are critical for engineers and buyers to understand. 1. Power Frequency High-Voltage Generators Operating Frequency: 50Hz/60Hz (same as standard power grid frequency). Characteristics: Large size and heavy weight due to low-frequency operation. Poor linearity in output, leading to inconsistent kV levels. Long exposure cycle times (minimum of 3ms), making it challenging to achieve precise dose control. Generates low-dose and "waste" X-rays, which reduce system efficiency and increase unnecessary radiation. Limitations: Inefficient for modern X-ray imaging due to high fluctuations in kV and dose instability. Heavy and bulky design makes it unsuitable for portable or high-precision applications. Applications: Traditionally used in older X-ray systems and for basic high-voltage testing. 2. Intermediate Frequency High-Voltage Generators Operating Frequency: 400Hz to 20kHz. Characteristics: Improved output linearity compared to power frequency generators, enabling more stable kV levels. Smaller size and lighter weight due to higher inverter frequencies. Reduced low-dose X-ray production, resulting in higher efficiency and better imaging quality. Advantages: Meets most conventional X-ray imaging and high-voltage testing needs. Balances size, weight, and performance for general-purpose applications. Limitations: While much improved over power frequency systems, it does not fully meet the demands of ultra-precise or high-speed applications. Applications: Suitable for standard X-ray photography and medium-precision high-voltage testing. 3. High-Frequency High-Voltage Generators Operating Frequency: Greater than 20kHz, typically above 40kHz. Characteristics: Highly stable output voltage (kV) with minimal fluctuations. Generates an almost linear kV waveform, ensuring consistent and precise performance. Capable of extremely short exposure times (as low as 1ms), ideal for high-speed imaging and testing. Compact and lightweight design, suitable for portable and space-constrained applications. Advantages: Low skin dose, high imaging quality, and large output doses for superior performance in medical imaging. Real-time control and ultra-short response times make it the gold standard for modern high-voltage equipment. Inverter frequencies above 40kHz deliver high precision, though frequencies beyond this threshold contribute marginally to further performance improvement. Applications: Widely used in advanced X-ray systems, high-precision testing, and modern portable high-voltage generators. Why Inverter Frequency Matters The inverter frequency of a DC high-voltage generator directly impacts its performance, size, weight, and application suitability: Higher Frequency Benefits: Reduced size and weight of the generator. Increased stability of kV output, resulting in more reliable performance. Enhanced imaging and testing precision. Trade-Offs: Extremely high frequencies (>40kHz) provide diminishing returns in performance improvements. High-frequency systems may have higher initial costs but offer long-term efficiency and accuracy. Conclusion DC high-voltage generators are classified into three categories based on their inverter frequency: power frequency, intermediate frequency, and high-frequency systems. For modern applications, high-frequency high-voltage generators are preferred due to their superior precision, compact design, and efficiency. However, intermediate frequency generators remain a viable option for conventional uses, while power frequency generators are largely obsolete for high-performance requirements. By understanding the differences in inverter frequency, new engineers and procurement professionals can make informed decisions when selecting high-voltage generators for their specific needs.
Read More
1 2 3 4 5 6 7 8 9 10 11 12