Product Details:
Payment & Shipping Terms:
|
Resolution: | 0.1A~10A: 1mA 10A~30A: 5mA | AC Output: | 0-120V 30A |
---|---|---|---|
DC Output: | 0-300V 20A | Frequency Output: | 10Hz-1000Hz |
High Light: | protective relay test set,protective relay tester |
Output 120V 30A Per Phase Relay Protection Tester Secondary Injection Relay Test set
ZX-1200 microcomputer relay protection Tester adopts high performance IPC as the controller, Window XP operating system, large size and color TFT screen, and industrial keyboard. The front panel is provided with a plurality of USB ports which is convenient for data access, data communication and software upgrades.
Features
Parameters
AC current source | Current source six phase with common neutral point, current up/down time<100μs | ||
Maximum output power | 300VA/phase | ||
Output accuracy | 0.1A~1A: accuracy: ±5mA | ||
1A~10A: accuracy: ±0.1% | |||
10A~30A: accuracy ±0.2% | |||
Resolution | 0.1A~10A: 1mA | ||
10A~30A: 5mA | |||
Single phase continuous output time | 1A~10A: No limit | ||
10A~20A: ≥60sec | |||
20A~30A: ≥50sec | |||
AC voltage source | Voltage source with six phase common neutral point, current up/down time<100μs | ||
Maximum output power | ≥75VA/phase | ||
Output accuracy | 1V~5V: ±5mV | ||
5V~120V: ±0.2% | |||
Resolution | 1V~5V: 1mV | ||
5V~120V: 5mV | |||
DC current source | Single phase output range | 0A~+10A | |
Maximum output power | 200VA/phase | ||
Output accuracy | ±0.1A~±2A: ±10mA | ||
±2A~±10A: ±0.5% | |||
Resolution | 5mA | ||
DC voltage source | Output range | -150V~+150V | |
Maximum output power | ≥100VA | ||
Output accuracy | ±1V~±5V: ±20mV | ||
Resolution | ±1V~±5V: 5mV | ||
±5V~±150V: 10mV | |||
AC voltage current source angle | phase angle range | 0°~360° | |
Accuracy | ±0.3° | ||
Resolution | 0.1° | ||
AC voltage current source frequency | range | 10~1000Hz | |
can overlap 2~20 order harmonic with any amplitude and direct current | |||
Output accuracy | 10Hz~65Hz ±0.005Hz | ||
65Hz~1000Hz ±0.02Hz | |||
Resolution | 0.001Hz | ||
Timing accuracy | 1ms~1S ±10ms | ||
1S~999999S ±0.2% | |||
Binary Input | 8 channels independent switch contact input, auto identify polarity of the active contact | ||
Binary Output | 4 pairs programmable idle contact output | ||
contact capacity: 250VDC, 0.5A or 250VAC, 0.5A | |||
synchronization | voltage current synchronization ≤50μS | ||
Power supply | AC input voltage | Rated value: 220V ± 10% | |
Reference value: 220V ± 2% | |||
AC power frequency | Rated value:50Hz ± 10% | ||
Reference value:50Hz ± 2% | |||
Working environment | temperature | -10℃~+40℃ | |
humidity | ≤90% | ||
air pressure | 80~110kPa |
Contact Person: Nie Qi
Tel: 86-18507140027