Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsHigh Voltage Test Equipment

Auto Testing High Voltage Test Equipment Dry Type Time Relay On - Off Condition

China Wuhan GDZX Power Equipment Co., Ltd certifications
China Wuhan GDZX Power Equipment Co., Ltd certifications
Product is good by performance, yes it is good for xxxxxx market.

—— Mr Dudani

Your product received very good, we will order one more piece

—— JS

You are very nice company. Thanks for your hospitality i spend very informative in your office

—— Yousri

Good for whatever the product or service, you got my trust through this deal.

—— Rahul

Very reliable supplier and partner, solving my question with great patience and perfession.

—— Gaurav

I'm Online Chat Now

Auto Testing High Voltage Test Equipment Dry Type Time Relay On - Off Condition

Auto Testing High Voltage Test Equipment Dry Type Time Relay On - Off Condition
Auto Testing High Voltage Test Equipment Dry Type Time Relay On - Off Condition Auto Testing High Voltage Test Equipment Dry Type Time Relay On - Off Condition Auto Testing High Voltage Test Equipment Dry Type Time Relay On - Off Condition Auto Testing High Voltage Test Equipment Dry Type Time Relay On - Off Condition

Large Image :  Auto Testing High Voltage Test Equipment Dry Type Time Relay On - Off Condition

Product Details:

Place of Origin: CHINA
Brand Name: GDZX
Certification: ISO9001
Model Number: GTB

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: $1043.47-6463.76
Packaging Details: wooden box
Delivery Time: 8-10work days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 1500sets/ year
Detailed Product Description
Transformer Type: Dry Type Controller: Manual Or Auto
Test Voltage: 50kV, 100kV.. V Regulation: Accuracy 1%
Output Distortion: ≤1% Waveform: Sine Wave
High Light:

electronic test equipment

,

high potential test equipment

Auto High Voltage  Dry type Testing Transformer

Hipot Test Equipment

 


Product Describtion :

 

GTB series adopts the new technology of coil winding epoxy vacuum pouring and CD type iron core. Comparing with the same kind of oil immersed transformer, it obviously reduces the weight and volume, improves the insulation strength and the anti humid range in the quality, and effectively weakens the magnetic leakage. The transformer is strong enough to withstand short-circuit current impact.

This series of devices are suitable for the power system and the electric power users to test the insulation performance of various electrical equipment in the field, or working as high voltage source.

Small and light, with compact structure, no oil leakage, maintenance unnecessary, simple wiring

 

Product Features:

  1. Small and light, with compact structure, no oil leakage, maintenance unnecessary
  2. The connecting wire is simple and intuitive, easy to use
  3. Reliable and with good appearance
  4. With over-voltage protection function
  5. Voltage, current, timing and results clearly displayed on 5.7 inch screen with backlight
  6. Sound and light alarm for working status reminding, easy to operate
  7. Touch panel, safe and reliable,
  8. Digital adjustment, convenient to use
  9. Keyboard to input current and voltage ratio
  10. Over-voltage, over-current protection, accurate and safe
  11. One key to chose AC or DC mode
  12. During auto testing, voltage increase and decrease can be paused at any time
  13. Strong anti-interference ability
  14. Auto cut off voltage output and alarm when the HV/LV current is over setting value.
  15. Time relay on-off condition can be set, and time range: 1-9999 seconds
  16. Customized service, optional functions like remote communications, other interfaces
  17. Little volume, light weight, compact structure, can stand wear and tear

Technical indicators :

 

  1. output voltage waveform: sine wave
  2. output waveform distortion rate: ≤ 1%
  3. no-load loss: 0.2% ~ 0.35%
  4. induced voltage level: 1.1 rated voltage /1min
  5. short-circuit impedance of single one test transformer is 4.5%~12% (+ 10%).
  6. voltage regulation precision is: 1%
  7. voltage instability: < 1%
  8. overvoltage protection function.
  9. surface temperature rise: <55℃
  10. rated capacity, allow continuous operation time:0.5 hours
  11. long time running transformer can be customized
  12. interrupted running time: <10kVA, 2 hours interval, continuous 0.5 hours.
  13. interrupted running time: <15kVA, 4 hours interval, continuous 0.5 hours.
  14. running continuously for 4 hours allowed under half rated voltage & half rated current

 

Model sereis : 

 

Model CAP Input (V) Output(kV) Output Output Max Size(mm) Weight
(kVA) (mA) DC (kV) (kg)
GTB-1.5/50 1.5 200 (400) 50 30 70 250×180×370 13
GTB-3/50 3 60 330×270×550 30
GTB-5/50 5 100 400×330×670 47
GTB-6/50 6 120 400×330×670 47
GTB-10/50 10 200 430×370×750 68
GTB-20/10 20 200 (100) 10 2000 / 470×370×750 83
GTB-20/50 20 200 (400) 100 400 70 470×370×750 85
GTB-30/50 30 600 520×410×780 120
GTB-5/100 5 50 140 430×370×1100 66
GTB-10/100 10 100 470×370×1100 77
GTB-20/100 20 200 520×410×1050 120
GTB-30/100 30 300 600×140×1050 160
GTB-50/100 50 500 650×460×1010 230

Auto Testing High Voltage Test Equipment Dry Type Time Relay On - Off Condition 0


Our Sevice :
 

 

1.png

Professional Consulting Services

Detailed Information About Products

Reasonable Price

Welcome Customer Visit

 

2.png

 

 

 

Signing Contracts And Technical Agreements

Ensure Execution Of Contract And Agreement

Active Communication

Complete After-Sales Service

 

logo.png

Professional After-Sale Service Team

1 Year Free Warranty, Life-Long Maintenance

Help Troubleshooting Within 24 Hours

Professional R & D Team

 

 

Contact Details
Wuhan GDZX Power Equipment Co., Ltd

Contact Person: Jaly

Send your inquiry directly to us (0 / 3000)