Send Message

Wuhan GDZX Power Equipment Co., Ltd sales@gdzxdl.com 86--17396104357

Wuhan GDZX Power Equipment Co., Ltd Company Profile
products
Home > products > High Voltage Test Equipment > Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1%

Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1%

Product Details

Place of Origin: CHINA

Brand Name: GDZX

Certification: ISO9001

Model Number: ZGF

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: carton

Payment Terms: L/C, T/T, Western Union, MoneyGram

Get Best Price
Product Details
Highlight:

high voltage test kit

,

electronic test equipment

Product Description

DC High Voltage Generator High Voltage Test Equipment DC Hipot Tester

 

Function: for DC high voltage test of zinc oxide arresters, power cables, generators, transformers, etc.

Features

1. Aluminum alloy carrying box

2. With High Frequency Voltage-multiplying circuit, PWM technology and high power IGBT device

3. Adopts voltage feedback, Higher voltage stability, smaller ripple coefficient.

4. Full range smooth voltage regulation, regulation accuracy≤1%, stability≤1%, voltage current error +/-1.5%±d

5. Raise voltage from zero voltage potentiometer

6. The 75% UDC 1mA function button is convenient for Zinc Oxide Arrester test.

7. Over voltage cylinder uses dialing number set, and the error +/-2%.

8. It’s coated with special insulating materials with good electric performance and water resistance

9. The product conform to DL/T848.1-2004 technology requirement, also passed test of quality inspection

Parameter:

Rated voltage: 60kV/120kV, Rated current: 2mA/3mA/5mA

Power supply: AC220V±10%, 50Hz

Ripple coefficient: ≤3.0%

Voltage measuring accuracy: ±(1.5 %reading±2digit)

Voltage stabilization: stochastic wave, ≤1% when power wave±10%

 

           Specification

 

 

Parameters 

60/2 60/5 120/2 120/5 120/10 200/2 200/5 200/10 300/2 300/5
Rated Voltage (kV) 60 60 120 120 120 200 200 200 300 300
Rated Current(mA) 2 5 2 5 10 2 5 10 2 5
Rated Power (W) 120 300 240 600 1200 400 1000 2000 600 1500
Box Weight (kg) 8 8 2 5 9 4.5 4.5 5.5 5.5 5.5
High voltage cylinder Weight (kg) 4 5 6 8 9 7 8.3 9.3 11 11.5
High voltage cylinder Hegiht (mm) 440 440 535 535 750 890 970 980 1250 1250
Voltage measuring accuracy Digital Meter ±(1.5%reading±2words)
Current measuring accuracy Digital Meter ±(1.5%reading±2words)
Ripple factor ≤3%
Voltage stability Random fluctuations, changes ≤1% when power supply±10%
Over Load capacity No load voltage can be 10% more than rated voltage working 10 mimutes, maximum charging current is 125% the rated current
Power supply Single phase AC 50HZ 220V±10%
Working way Intermittently
One time continuous working: 10 minutes
Working environment Temperature: 0~40℃
Relative Humidity is no more than 85% when room temperature is 25℃(No condensation)
Altitude: below 1500 meters
Structure character Exopy glass steel electrical insulated high voltage cyclinder
Air insulation, no worry of leakage
Operation box character High precision 0.75UDC1mA single touch button (accuracy≤2.0%), most suitable for zinc oxide arrester test
Dialing number set for overvoltage protection
All in an aluminum alloy box, integrated structure, portable

Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1% 0Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1% 1Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1% 2Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1% 3Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1% 4Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1% 5Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1% 6Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1% 7Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1% 8

Compact DC High Voltage Test Set , Electronic Test Equipment Regulation Accuracy ≤1% 9