Send Message

Wuhan GDZX Power Equipment Co., Ltd sales@gdzxdl.com 86--17396104357

Wuhan GDZX Power Equipment Co., Ltd Company Profile
products
Home > products > High Voltage Test Equipment > JF-2002 High Voltage Test Kit /High Voltage Partial Discharge Detector

JF-2002 High Voltage Test Kit /High Voltage Partial Discharge Detector

Product Details

Place of Origin: CHINA

Brand Name: GDZX

Certification: ISO9001

Model Number: ZXJF-2002

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $3,500.00 - $5,000.00 / Sets

Packaging Details: carton

Delivery Time: 8-15 work days

Payment Terms: L/C, T/T, Western Union, MoneyGram

Supply Ability: 600 Case/Cases per Year

Get Best Price
Product Details
Highlight:

high voltage test kit

,

high potential test equipment

Tested product capacity:
6PF-250μF
Frequency:
<50, 100, 150, 220, 400Hz
Brand:
GDZX
Range:
100kV ( Can Expand )
Accuracy:
± 3%
Product Name:
Partial Discharge Detector
Tested product capacity:
6PF-250μF
Frequency:
<50, 100, 150, 220, 400Hz
Brand:
GDZX
Range:
100kV ( Can Expand )
Accuracy:
± 3%
Product Name:
Partial Discharge Detector
Product Description

ZXJF-2002 Partial Discharge Detector /PD Detector


 

Product brief introduction :

 

ZXJF-2002 partial discharge detector is a new type of analog partial discharge detector developed by our company. It retains the advantages of its predecessor, while reducing the size, and further optimizing the performance, making it more complete, more convenient to use, and more efficient. reliable.

 

The PD Detector uses 32 high-performance single-chip circuits, combined with the digital pulse potentiometer knob, which not only improves the service life of the operation, but also adds the following functions: one-button automatic calibration; high voltage test voltage divider ratio can be set; serial communication upload test data. The instrument has the characteristics of high detection sensitivity, wide range of applicable test samples, large dynamic range of the amplification system, multiple frequency band combinations (nine types), and strong anti-interference ability. This instrument is used in conjunction with the calibration pulse generator and input unit, and is a practical partial discharge test instrument widely used by power departments, manufacturers and scientific research institutes.

Product characteristics :

1. High measuring sensitivity, wide application, high signal-to-noise ratio

2. Equipped with large screen oscillometer, clear display with high frequency oval sweep (uptake power less than 1VA), 9 groups of frequency bands, discharge impulse amount can be read directly

3. This detector usually work with Correcting impulse generator. It is widely applied in power stations, manufacturers and institutions.

 


Parameter:

1. Tested product capacity: 6PF - 250μF.

2. See below table:

Input

Unit

Turning capacitance

Sensitivity(pC

(Unsymmetrical

Circuit)

permissible current RMS

Unsymmetrical

Circuit

Symmetrical

Circuit

1

0~25~100pF

0.02

30mA

0.25A

2

25~100~400pF

0.04

50mA

0.5A

3

100~400~1500pF

0.06

120mA

1A

4

400~1500~6000pF

0.1

0.25A

2A

5

1500~6000~25000pF

0.2

0.5A

4A

6

0.006~0.025~0.1μF

0.3

1A

8A

7

0.025~0.1~0.4μF

0.5

2A

15A

8

0.1~0.4~1.5μF

1

4A

30A

9

0.4~1.5~6.0μF

1.5

8A

60A

10

1.5~6.0~25μF

2.5

15A

120A

11

6.0~25~60μF

5

25A

200A

12

25~60~250μF

10

50A

300A

7R

Resistance

0.5

2A

15A

3. Oval Time Base:

Frequency: <50, 100, 150, 220, 400Hz
Ellipse Rotation: each gear 30°, 360°rotation can be made
Display: Oval –extend– straight line.
High-frequency time base elliptical input voltage 10~250V, intake power < 1 VA, with over-load protection

4. Display:

124x10mm rectangle oscillometer, brilliant and focus adjustment button

5. Amplifier

1) 3dB low frequency band: 10KHZ, 20 KHZ, 40 KHZ (selectable),

2) 3dB High frequency band: 80 KHZ, 200 KHZ, 300 KHZ (selectable)

3) Regulation: coarse control- there are 6 gears for coarse tuning, the gain of each gear is 20±1db, fine control ≥ 20 db

4) positive and negative pulse response asymmetry<1dB

6. Time Window:

Window width : Adjustable range 15° ~ 150°;
Window position : Each window can be rotated 0°~ 170°;
Two time windows can be opened separately or simultaneously.

7. Discharge scale:

Linear pointer type headers: 0-100 error±5% (full scale)

Logarithm pointer type headers: 0-10-100 error ±5% (full scale)

Digital meter: 31/2 LED display figures: 0-100 error ± 3% (full scale)

8. Testing voltage meter

Range : 100kV ( can expand )
Display : 3 ½ digit voltmeter indication
Accuracy: ± 3%

9. Zero Mark function

10. Dimension: 530X550X220mm, Weight about 22 KG

Correcting impulse generator parameters:

1. Output electric charge :5pC,10pC,20pC,50Pc

2. Polarity: Positive or negative , Alternative

3. Repetition frequency: 1.2kHz

4. Frequency varying range: >±100Hz

5. Impulse setting edge time:<60nS

6. Impulse drop edge time: >100uS

7. Injection capacitance:10pF

8. Correcting charge error: Eq≤±10%

9. Dimension: 160×125×50mm3

10. Weight: 0.5kg

11. Battery: 6F22 9V

JF-2002 High Voltage Test Kit /High Voltage Partial Discharge Detector 0


 

Our Sevice :
 

 

1.png

Professional Consulting Services

Detailed Information About Products

Reasonable Price

Welcome Customer Visit

 

2.png

 

 

 

Signing Contracts And Technical Agreements

Ensure Execution Of Contract And Agreement

Active Communication

Complete After-Sales Service

 

logo.png

Professional After-Sale Service Team

1 Year Free Warranty, Life-Long Maintenance

Help Troubleshooting Within 24 Hours

Professional R & D Team

 

JF-2002 High Voltage Test Kit /High Voltage Partial Discharge Detector 4