Product Details

Place of Origin: CHINA

Brand Name: GDZX

Certification: ISO9001

Model Number: ZXBX-12

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: carton

Payment Terms: L/C, T/T, Western Union, MoneyGram

Get Best Price
Product Details
Highlight:

power quality meter

,

portable power quality analyser

Voltage:
-10V~10V, -200V~200V, -400V~400V
Current:
-20mA~20mA
Display:
LCD
Accuracy:
0.02
Voltage:
-10V~10V, -200V~200V, -400V~400V
Current:
-20mA~20mA
Display:
LCD
Accuracy:
0.02
Product Description

 

This device is transient signal recorder and analyzer designed for power application system.

Test functions:

Generator short circuit test

Generator unloaded test,

Excitation system disturbance test,

10% step test

Magnet lost test

Synchronizing test,

load rejection recording test

Other electric value measuring and recording test

Back software:

Software: Perfect functions of waveform display, edition, alternation, combination, comparing, additional mark and selected print, calculation of power value,

Data export into WORD/EXCEL/JPG files

Features

1. 12 Analog input channels, 12 active binary input channels and 3 binary output channels.

2. Maximum sampling frequency up to 100KHz. All the analog channels are isolated with each other

3. Real time curve drawing and curve analysis, allow user’s curve scaling and positioning operation

4. Graphics edit function on present oscilloscope, freely labeling, color conversion

5. The spectrum analysis tool allows users to easily access signal spectrum graph.

6. Any signal can be selected to be X-axis Y-axis drawing signal relation curve.

7. Its harmonic analysis tool can do harmonic analysis of acquired signals, harmonic up to 1024th order

8. Combination calculation tool for addition, subtraction, multiplication, division and integration

9. RMS and power calculation for the selected channel

10. Power and symmetry analysis on selected three phase signal

11. Phasor diagram drawing for selected signal

12. Channel signal type to choose through software: DC transient value or AC effective value

13. Built in standard test templates, auto calculate testing result parameters

14. Auto generate word testing report and excel testing report

15. Auto identify relative curves to realize full automation of testing report preparing

16. Can re-define all sampling channel names and units

17. Auto save various test environment settings and instrument settings

18. Auto calculate test parameters of various test templates.

19. Simple and convenient channel filtering.

Parameters:

1. 12 channel voltage/current analog acquisition:

    voltage input range: -10V~10V, -200V~200V, -400V~400V

    current input range: -20mA~20mA

    one channel for analog input -100mV~100mV

2. Though software to select voltage channel input range, voltage or current signal type

3. Deviation of signal acquisition:

   -400V~400V, error<0.5V
   -200V~200V, error<0.2V
   -10V~10V, error<0.01V
   -20mA~20mA, error<0.02mA
   -100mV~100mV, error <0.2mV

4. 12 active contact switching value measurement channels, signal range DC12-220V

5. 3 binary output channels, the largest output breaking capacity of AC220V/1A

6. Split type cabinet structure, convenient for terminal users to control test and analyze data

7. Two USB ports for data download or keyboard/mouse input.

8. Large color LCD display, touch panel for human-computer interaction

9. 8G memory

10. Sampling channel input impedance:

    -10V~10V voltage tap position, input impedance 820kΩ
    -200V~200V voltage tap position, input impedance 820kΩ
    -400V~400V voltage tap position, input impedance 820kΩ
    -20mA~20mA current tap position, input impedance 50Ω
    -100mA~100mA voltage tap position, input impedance>10MΩ