Product Details:
Payment & Shipping Terms:
|
Product Name: | DC High Voltage Test | Power Supply: | Single Phase AC 50HZ 220V±10% |
---|---|---|---|
Working Way: | Intermittently | Temperature: | 0~40℃, ≤85%RH |
Altitude: | < 1500 Meters | Power: | Electronic |
High Light: | high voltage test kit,electronic test equipment |
1. Aluminum alloy carrying box
2. With High Frequency Voltage-multiplying circuit, PWM technology and high power IGBT device
3. Adopts voltage feedback, Higher voltage stability, smaller ripple coefficient.
4. Full range smooth voltage regulation, regulation accuracy≤1%, stability≤1%, voltage current error +/-1.5%±2d
5. Raise voltage from zero voltage potentiometer
6. The 75% UDC 1mA function button is convenient for Zinc Oxide Arrester test.
7. Over voltage cylinder uses dialing number set, and the error +/-2%.
8. It’s coated with special insulating materials with good electric performance and water resistance
9. The product conform to DL/T848.1-2004 technology requirement, also passed test of quality inspection
Parameter
Rated voltage: 60kV/200kV, Rated current: 2mA/3mA//5mA
Power supply: AC220V±10%, 50Hz
Ripple coefficient: ≤3.0%
Voltage measuring accuracy: ±(1.5 %reading±2digit)
Voltage stabilization: stochastic wave, ≤1% when power wave±10%
Specification Parameters |
60/2 |
60/5 |
120/2 |
120/5 |
120/10 |
200/2 |
200/5 |
200/10 |
300/2 |
300/5 |
Rated Voltage (kV) |
60 |
60 |
120 |
120 |
120 |
200 |
200 |
200 |
300 |
300 |
Rated Current(mA) |
2 |
5 |
2 |
5 |
10 |
2 |
5 |
10 |
2 |
5 |
Rated Power (W) |
120 |
300 |
240 |
600 |
1200 |
400 |
1000 |
2000 |
600 |
1500 |
Box Weight (kg) |
8 |
8 |
2 |
5 |
9 |
4.5 |
4.5 |
5.5 |
5.5 |
5.5 |
High voltage cylinder Weight (kg) |
4 |
5 |
6 |
8 |
9 |
7 |
8.3 |
9.3 |
11 |
11.5 |
High voltage cylinder Hegiht (mm) |
440 |
440 |
535 |
535 |
750 |
890 |
970 |
980 |
1250 |
1250 |
Voltage measuring accuracy |
Digital Meter ±(1.5%reading±2words) |
|||||||||
Current measuring accuracy |
Digital Meter ±(1.5%reading±2words) |
|||||||||
Ripple factor |
≤3% |
|||||||||
Voltage stability |
Random fluctuations, changes ≤1% when power supply±10% |
|||||||||
Over Load capacity |
No load voltage can be 10% more than rated voltage working 10 mimutes, maximum charging current is 125% the rated current |
|||||||||
Power supply |
Single phase AC 50HZ 220V±10% |
|||||||||
Working way |
Intermittently |
|||||||||
One time continuous working: 10 minutes |
||||||||||
Working environment |
Temperature: 0~40℃, ≤85%RH, Altitude < 1500 meters |
|||||||||
Structure character |
Exopy glass steel electrical insulated high voltage cyclinder, Air insulation, no worry of leakage |
|||||||||
Operation box character |
Precision 0.75UDC1mA single touch button (accuracy≤2.0%), most suitable for zinc oxide arrester test |
|||||||||
Dialing number set for overvoltage protection |
||||||||||
All in an aluminum alloy box, integrated structure, portable |
Contact Person: Nie Qi
Tel: 86-18507140027