Wuhan GDZX Power Equipment Co., Ltd sales@gdzxdl.com 86--17362949750
Product Details
Place of Origin: China
Brand Name: GDZX
Certification: ISO9001
Model Number: ZXET3008
Payment & Shipping Terms
Minimum Order Quantity: 1Set
Price: US $ 1099.00-2239.00/SET
Packaging Details: Packing wooden case or carton
Delivery Time: 7-12 work days
Payment Terms: L/C,T/T,Western Union,MoneyGram,WeChat,Paypal
Supply Ability: 1200sets/year
Product Name: |
Double Clamp Ground Resistance Tester |
Power Supply: |
DC 7.4V 1.8Ah Rechargeable Lithium Battery |
Back Light: |
Controllable White Screen Backlight, Suitable For Use In Dark Places |
Test Frequency: |
128Hz/111Hz/105Hz/94Hz(Automatic Frequency Selection) |
Test Voltage Waveform: |
Sine Wave |
Short Circuit Test Current: |
AC 20mA Max |
Line Voltage: |
Measurement Below AC 100V |
Communication Interface: |
With USB Interface, The Stored Data Can Be Uploaded To The Computer, Save And Print |
Working Temperature And Humidity: |
-10 ℃ ~ 40 ℃; Below 80% Rh |
Insulation Resistance: |
20MΩ Or More (500V Between Circuit And Case) |
Product Name: |
Double Clamp Ground Resistance Tester |
Power Supply: |
DC 7.4V 1.8Ah Rechargeable Lithium Battery |
Back Light: |
Controllable White Screen Backlight, Suitable For Use In Dark Places |
Test Frequency: |
128Hz/111Hz/105Hz/94Hz(Automatic Frequency Selection) |
Test Voltage Waveform: |
Sine Wave |
Short Circuit Test Current: |
AC 20mA Max |
Line Voltage: |
Measurement Below AC 100V |
Communication Interface: |
With USB Interface, The Stored Data Can Be Uploaded To The Computer, Save And Print |
Working Temperature And Humidity: |
-10 ℃ ~ 40 ℃; Below 80% Rh |
Insulation Resistance: |
20MΩ Or More (500V Between Circuit And Case) |
ZXET3008 Double Clamp Ground Resistance Tester
Product introduction
The ZXET3008 Double-clamp Grounding Resistance Tester is carefully designed and manufactured for field measurement of grounding resistance, soil resistivity, grounding voltage, grounding wire leakage current, AC current, and DC resistance in combination with the new lightning protection grounding resistance detection standard. Current up to 20mA, using digital processing technology, precision 4-wire method, 3-wire method and simple 2-wire method, selection method, double clamp method to measure the grounding resistance, large-caliber current clamp design, can measure the grounding system using large grounding down conductor.
Features
1. Double clamp method, selection method, two, three, four wire method to test the grounding resistance;
2. Loop resistance, on-resistance, DC resistance, equipotential connection resistance test;
3. Soil resistivity, AC current, leakage current, ground voltage test;
4. Designed according to the new standard for meteorological lightning resistance grounding resistance test;
5. The grounding resistance test current reaches 20mA;
6. Special tool box design, durable;
7. The toolbox can be selected in black or yellow;
8. FFT technology, AFC technology, strong anti-interference ability;
9. Range: 0.000Ω ~ 30000Ω; 0 ~ 100V; 0 ~ 600A;
10. Resolution: 0.001Ω; 0.1V; 0.1mA.
Functions | Ground resistance, soil resistivity, DC resistance, on-resistance, equipotential connection resistance, ground voltage, AC current, leakage current measurement |
Power supply | DC 7.4V 1.8Ah rechargeable lithium battery |
Back light | Controllable white screen backlight, suitable for use in dark places |
Measurement | Precision 4-wire, 3-wire method measurement, simple 2-wire method, selection method, double clamp method to measure grounding resistance |
Measurement methods | Two, three and four wire method measurement: pole changing method, short circuit measurement current 20mA Max |
Selection method measurement: pole changing method, short circuit measurement current 20mA Max | |
Double clamp method: non-contact mutual inductance measurement method, test current 1mA Max | |
Soil resistivity: quadrupole method (Wenner method) | |
DC resistance: pole changing method | |
AC current: average rectification (clamp) | |
Voltage to ground: average rectification (between P (S) -ES interface) | |
Range | Two, three, four wire method to measure grounding resistance (R): 0.000Ω ~ 30000Ω |
Selection method to measure grounding resistance (Re): 0.00Ω ~ 3000Ω | |
Double clamp method to measure grounding resistance (Re): 0.01Ω ~ 200Ω | |
Double clamp method to measure grounding resistance (Re): 0.01Ω ~ 200Ω | |
Ground voltage (50Hz / 60Hz): AC 0.0 ~ 100.0V | |
Alternating current (50Hz / 60Hz): AC 0.00mA ~ 600.0A | |
Highest resolution |
Two, three, four wire method to measure grounding resistance (Re), DC resistance:0.001Ω(0.000Ω~29.999Ω); 0.01Ω(30.00Ω~299.99Ω) 0.1Ω(300.0Ω~2999.9Ω);1Ω(3000Ω~30000Ω) |
Selection method for measuring grounding resistance (Re): 0.01Ω(0.00Ω~29.99Ω);0.1Ω(30.0Ω~299.9Ω) 1Ω(300Ω~3000Ω) |
|
Double clamp method to measure grounding resistance (Re): 0.01Ω(0.01Ω~0.99Ω);0.1Ω(1.0Ω~29.9Ω) 1Ω(30Ω~200Ω) |
|
Soil resistivity (ρ): 0.01Ωm(0.00Ωm~99.99Ωm) 0.1Ωm(100.0Ωm~999.9Ωm) 1Ωm(1000Ωm~9999Ωm) 10Ωm(10.00kΩm ~99.99kΩm) 100Ωm(100.0kΩm~999.9kΩm) 1kΩm(1000kΩm~9000kΩm) |
|
Ground voltage(50Hz/60Hz): 0.1V | |
AC current(50Hz/60Hz): 0.01mA | |
Precision |
Two, three, four wire method to measure grounding resistance (Re), DC resistance (R-): ±2%rdg±0.05Ω (0.000Ω~29.999Ω) ±2%rdg±3dgt (30.00Ω~299.99Ω) ±2%rdg±3dgt (300.0Ω~2999.9Ω) ±4%rdg±3dgt (3.000kΩ~30.00kΩ) Note: 1. Additional error at rC max or rP max≤±5%rdg±5dgt.(rC max:4kΩ+100R<50kΩ, rP max:4kΩ+100R<50kΩ) 2. Additional error at 5V interference voltage≤±5%rdg±5dgt |
Selection method for measuring grounding resistance (Re): ±2%rdg±5dgt(0.00Ω~29.99Ω) ±2%rdg±3dgt(30.0Ω~299.9Ω) ±2%rdg±3dgt (300Ω~3000Ω) |
|
Double clamp method to measure grounding resistance (Re): ±10%rdg±5dgt(0.01Ω~100Ω) ±20%rdg±5dgt(101Ω~200Ω) |
|
Soil resistivity (ρ): according to the measurement accuracy of R (ρ=2πaR a:1 m~100m;π=3.14) |
|
Ground voltage(50Hz/60Hz): ±2%rdg±3dgt | |
AC current(50Hz/60Hz): ±2%rdg±3dgt | |
Test voltage waveform | Sine wave |
Test frequency | 128Hz/111Hz/105Hz/94Hz(Automatic frequency selection) |
Short circuit test current | AC 20mA max |
Open circuit test voltage | AC 40V max |
Electrode spacing | 1m~100m |
Display mode | 6-digit large LCD display with backlight |
Measurement instructions | LED flashing indication during measurement, LCD countdown display |
LCD size | 128mm×75mm |
LCD display | 124mm×67mm |
Size | Instrument size: length, width and height 320mm × 275mm × 145mm |
Current clamp: length, width and height about 220mm × 100mm × 27mm | |
Package dimensions | Outer package: length, width and height about 400mm × 245mm × 335mm |
Standard test line | Red 15m, Black 15m, Yellow 10m, Green 10m |
Simple test line | 2 bars: red 1.6m, black 1.6m |
Auxiliary ground rod | 4 piece:φ10mm×150mm |
Current clamp | 2 pcs: CT1 clamp red black plug, CT2 clamp blue black plug |
Current clamp caliber | φ52mm |
Current clamp caliber | 1000:1 |
Current clamp lead | Length 2m |
Measure time |
AC current: about 2 times / second; Ground voltage: about 2 times / second; Ground resistance: about 7 seconds / time |
Measurement times | More than 5000 times (short circuit test, test once, stop for 30 seconds and then test) |
Line voltage | Measurement below AC 100V |
Communication Interface | With USB interface, the stored data can be uploaded to the computer, save and print |
Communication line | 1 USB communication line, 1.5m long |
Data retention | "HOLD" symbol indicates when holding data |
Data storage | 2000 groups, "MEM" storage indication, display "FULL" indicates that the storage is full |
Data access | "READ" symbol indicates when checking data |
Overflow display | "OL" symbol indication when over-range overflow |
Current clamp low current indication | When selecting the method or the double clamp method, when the current signal received by the CT2 clamp is lower than 0.5mA, the symbol "" is displayed. At this time, the clamp direction of the CT2 current clamp should be checked |
Interference test | Automatically identify the interference signal, the interference voltage is higher than 5V "NOISE" symbol indication |
Auxiliary ground test | With auxiliary earth resistance value test function, 0.00kΩ~30.00kΩ(100R+rC<50kΩ,100R+rP<50kΩ) |
Alarm function | When the measured value exceeds the alarm setting value, "beep--beep--beep--" alarm prompt |
Battery voltage | When the battery voltage is insufficient, the battery voltage low symbol is displayed to remind the battery to charge. |
Automatic shut-down | Automatic shutdown after 15 minutes |
Working current |
Standby: 25mA Max (backlight off); Backlight: 25mA Max (separate backlight power consumption); When measuring: 150mA Max (backlight off) |
Weight | Instrument: 2.66kg (including battery) |
Total weight: 7.87kg (including packaging) | |
Tool box | Special toolbox design, can bear 200kg |
Working temperature and humidity | -10 ℃ ~ 40 ℃; below 80% rh |
Storage temperature and humidity | -20 ℃ ~ 60 ℃; below 70% rh |
Overload protection | Measurement of grounding resistance: AC 280V / 3 seconds between C (H) -E, P (S) -ES ports |
Insulation resistance | 20MΩ or more (500V between circuit and case) |
Withstand | 20MΩ or more (500V between circuit and case) |
Electromagnetic characteristics | IEC61326(EMC) |
Suitable for safety regulations |
IEC61010-1 (CAT Ⅲ 300V, CAT IV 150V, pollution degree 2); IEC61010-031; IEC61557-1 (ground resistance); IEC61557-5 (soil resistivity); JJG366-2004 (ground resistance meter); JJG1054-2009 (clamp ground resistance meter). |
Product pictures
(1)We will ship products within 5-20 working days after the receipt of confirmation of your payment.
(2)All products will be well packed by robust carton or wooden box so as to ensure goods can arrive safely.
(3)Multiple shipping methods including express, sea freight, railway and so on for your choice, competitive shipping method will be advised to you.
(4)If you go with your own forwarder, we will provide all necessary documents for customs clearance.
(5)After shipping, we will remain attentive till goods well received.
Wuhan GDZX Power Equipment Co.,Ltd. is a manufacturer of power test equipment. Integrating design , production and sales, providing complete solutions for high-voltage testing and electrical testing services for various power users.The main products include:AC series resonance test device, high voltage test equipment, transformer test equipment, secondary protection / switch test equipment, cable fault tester, arrester test equipment, power metering equipment, standard source series and so on. There are many kinds of products and complete models.
Service
* Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions.
* Ensure customer get the detailed information about the product in hand.
* Reasonable price, we trust our customers should get the worth what they paid. Quotation stamped and confirmed by Manager.
* Welcome customers visit.
* The contract and the technical agreement to sign by both parties.
* Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements.
* Focus on communication, actively communicate with users, take notes of user’s questions and schedule, provide the necessary technical support.
* Move quick and efficient, professional on delivery, installation, debugging, training and others.
Warranty
* We maintains 100% customer satisfaction, please give us feedback if you fell anything wrong with the product, we will make it right for you.
* Our products are guaranteed with one year warranty and life-long tech support.
* Provide solutions within 24 hours when there is problems feedback from customer.
1.Q: Are you trading company or manufacturer?
A: We are manufacturer.
We have R&D department, OEM& ODM services available.
2.Q: How long is your delivery time?
A: We usually arrange shipment within 5-7 working days after checking the payment. However, for example, the delivery time of the complete set of test devices will be a little longer, which needs to be checked in real time.
3.Q: Do you provide samples? Is it free or extra?
A: Yes, we could offer the sample, but not for free; you need pay charge and the cost of freight.
4.Q: What is your term of payment?
A: Payment<=5000USD, 100% in advance. Payment>=5000USD, 40% T/T in advance, balance before shipment.
5.Q: What is the payment method?
A: We can accept Bank Transfer, T/T, PayPal, Western Union, Money Gram, Cash etc.
6.Q: Will you provide OEM service?
A: OEM & ODM services available
7.Q: How long is the product warranty?
A: 1 year.